System Guide

SME VOIP SYSTEM GUIDE 4.7 64 | P a g e
Proprietary and Confidential
5.13 LAN SYNC
NOTE: To join one Base Station in a dual-cell system, you need to have one handset added to the system. For details
and Step-by-Step guide to dual cell, please see Appendix
In this section, we describe the different parameters available in the dual-cell configurations menu.
5.13.1 Settings for Base Unit
Description of Settings for Specific Base units is as follows:
Screenshot:
PARAMETERS
DEFAULT
VALUES
DESCRIPTION
MULTICAST IP
ADDRESS
224.0.1.129
IP address of the multicast group.
The IP address must start with 224.0.xx.xx this cannot be changed.
To be compliant with IEEE1588, this port must be default value.
Before setup, make sure no other devise uses the given IP.
NOTE: this should only be changed in case other IEEE1588 equipment is on the
network and using this specific IP address.
MULTICAST
PORT
319
Define the port that the system must communicate on
To be compliant with IEEE1588, this port must be default value.
NOTE: this should only be changed in case other IEEE1588 equipment is on the
network and using this specific port.
DOMAIN
NUMBER
0
Domain number is used to set what domain this specific base station belongs
to.
Valid input: 0-127
ALTERNATIVE
DOMAIN
NUMBER
64
Alternative domain is only used in case the primary sync source from the main
domain fails, this the base station will sync with the alternative domain.
Must NOT have same value as domain number.
Valid input: 0-127
MULTI CELL
DEBUG MODE
None
Enable this feature, if you want the system to catalogue low level multi-cell
debug information or traces.
Options:
Data Sync: Writes header information for all packets received and sent to be
used to debug any special issues. Generates LOTS of SysLog signaling and is
only recommended to enable shortly when debugging.
Auto Tree: Writes states and data related to the Auto Tree Configuration
feature.
Both: Both Data Sync and Auto Tree are enabled.
IEEE1588 Debug: Writes IEEE1588 debug information