System Guide

SME VOIP SYSTEM GUIDE 4.7 60 | P a g e
Proprietary and Confidential
5.12.3 Base System Settings
Description of SIP Settings for Specific Base units is as follows:
Screenshot
Parameter
Default Values
Description
NUMBER OF SIP
ACCOUNTS BEFORE
DISTRIBUTED LOAD
8
The maximum number of handsets or SIP end nodes that are permitted
to perform location registration on a specific Base unit before load is
distributed to other base units. The parameter can be used to optimize
the handset distribution among visible base stations.
Note: A maximum of 8 simultaneous calls can be routed through each
Base unit in a multi-cell setup.
Permitted Input: Positive Integers (e.g. 6)
SIP SERVER SUPPORT
FOR MULTIPLE
REGISTRATIONS PER
ACCOUNT
Disabled
Disable this option so it is possible to use same extension (i.e. SIP
Account) on multiple phones (SIP end nodes). These phones will ring
simultaneously for all incoming calls. When a phone (from a SIP
account group) initiates a handover from Base X to Base Y, this phone
will de-register from Base X, and register to Base Y after a call.
Permitted Input:
Disabled: No SIP de-registration will be made when a handset
roams to another base station
Enabled: The old SIP registration will be deleted with a SIP
Deregistration, when a handset roams to another base
station
SYSTEM
COMBINATION
(NUMBER OF BASE
STATIONS/REPEATERS
PER BASE STATION):
50/3
Select between basic base configurations.
50/3 : 50 bases and 3 repeaters
127/1 : 127 bases and 1 repeater
254/0 : 254 bases and 0 repeater
The configuration cannot be modified after a system is established. The