System Guide

SME VOIP SYSTEM GUIDE 4.7 45 | P a g e
Proprietary and Confidential
5.7 Firmware Update
In this page, the system administrator can configure how base stations and SIP nodes upgrade/downgrade to the
relevant firmware. Handset firmware update status can be found in the extensions page and repeater firmware
update status in the repeater page. Base firmware update status is found in the home/status page.
Screenshot
PARAMETER
DEFAULT
VALUE(S)
DESCRIPTION
FIRMWARE UPDATE
SERVER ADDRESS
Empty
IP address or DNS of firmware update files source
Valid Inputs: AAA.BBB.CCC.DDD or <URL>
Example: firmware.rtx.net or 10.10.104.41
FIRMWARE PATH
Empty
Location of firmware on server (or firmware update server path
where firmware update files are located).
Example: RTXFWU
TERMINAL FILE PATH
Empty
Location of image (folder where background and start up image are
located).
Example: Images
REQUIRED VERSION
Empty
Version of firmware to be upgraded (or downgraded) on handset,
repeater, or base station.
Valid Input(s): 8-bit string length. E.g. 400
Note: Value version 0 will disable firmware upgrade
Note: Two handset types will be serial firmware upgraded. First type
8630 then type 8430.
REQUIRED BRANCH
Empty
Branch of firmware to be upgraded (or downgraded) handset,
repeater or base station.
Valid Input(s): 8-bit string length. E.g. 01
STARTUP PICTURE
Empty
Name of the startup picture you want on the handsets when they are
powered up.
NOTE: Image have same resolution as the screen on the handset(s),
this can be found in the handset datasheets
If the image does not have the same resolution as the screen, it will
be placed in the top left corner. To small the rest of the screen will be
black. To large only the left portion of the image will be shown.
NOTE: Only .BMP is files are supported.
NOTE: Changing startup picture is not available for new GUI
(RTX8631/RTX8632 and RTX8633)