User's Manual

SME VoIP System Guide, Version 2.6
Proprietary and Confidential
Chapter:
Multi
-cell Setup & Management
86
6.4.4 Case ##4: Large Enterprises at Different Locations
In this scenario, multi-cell systems are deployed at different locations; geographically separated from each
other. Each location has a master base station with more than one slave base synchronise to it.
The procedure:
STEP 1 Follow the steps described in sections 6
STEP 2 On the Network page of each base define the DECT sync source settings as illustrated in the
table below.
STEP 3 Save and reboot each base to complete case ## 4 setup
STEP 4 Important for this configuration is to enable “Allow multi primary” on the multi cell page.
This allows the handset to locate on both systems make it possible for the user move from one
location to the other and still use the same handset.
Multi Cell Page of Base Stations
Recommended settings of MAC-units in Chain section of page (Other valid setting exists):
RPN
Ver
MAC Addr
IP Addr
IP Status
DECT sync
source
DECT
Property
00
XX
XX:XX:XX…
XXX.XXX…
Connected
0: RPN:00
Primary for
HQ
04
XX
XX:XX:XX…
XXX.XXX…
Connected
0: RPN:00
08
XX
XX:XX:XX…
XXX.XXX…
Connected
1: RPN:04