User's Manual

SME VoIP System Guide, Version 2.6
Proprietary and Confidential
Chapter:
Multi
-cell Setup & Management
84
6.4.2 Case ##2: Location with co-located partners
Example includes Department shops, Retail location with co-located photo kiosk or pharmacy, etc.
To illustrate this setup, two slave base stations are synchronised to one master base in the two office
blocks.
Here is diagram to illustrate Case ##2.
The procedure:
STEP 1 Follow the steps described in section 0
STEP 2 On the Network page of each base define the DECT sync source settings as illustrated in the
table below.
STEP 3 Save and reboot each base to complete case ##2 setup
Multi Cell Page of Base Stations
Recommended settings of MAC-units in Chain section of page (Other different settings exist):
RPN
Ver
MAC Addr
IP Addr
IP Status
DECT sync
source
DECT
Property
00
XX
XX:XX:XX…
XXX.XXX…
Connected
1: RPN:04
04
XX
XX:XX:XX…
XXX.XXX…
Connected
1: RPN:04
Primary
08
XX
XX:XX:XX…
XXX.XXX…
Connected
1: RPN:04