6.3 Summary of Procedure Creating a Chain
We enumerate the short version of how to add 3 base stations units in a multi-cell setup. This can be
applied for up to 40 number of base units.
This procedure is divided into four (4) main stages. Apply this procedure if all base unit are straight from
production.
6.3.1 Stage 1
Skip this stage if relevant base stations are already in the network.
a) Add 3 base stations i.e. RFP1, RFP2, RFP3 > Disable theMulti cell system” option and “Save”
b) RFP1, RFP2, RFP3: Reboot from the HTTP SME Configuration Main Page
c) RFP1, RFP2, RFP3: Default by pressing reset button 12-sec.
6.3.2 Stage 2
Choosing 1
st
base unit i.e. RFP1 as Primary
a) RFP1: Define Time server and “Save and reboot from the Time page
b) RFP1: Reboot automatically
c) RFP1: Press “Add server” and define SIP server IP and “Save” from the Servers page
d) RFP1: On the extension page add one extension (no handset needs to be registered). This step is
important for allow secondary base to join
e) RFP1: Multi cell system = enable and “Save” from the Multi-cell page
f) RFP1: Reboot (Verify from Debug log “SYNCMGR: This base is ready to be Primary in a Chain”)
6.3.3 Stage 3
Choose another base unit,RFP2 as Secondary
a) RFP2: Select chain ID same as RFP1.
b) RFP2: Multi cell system = enable and “Save”
c) RFP2: Reboot (Verify from Debug log “SYNCMGR: This base is ready to join into another Chain”)
d) RFP1, RFP2: Wait 2min for stable Primary-Secondary chain (check for the message: SYNCMGR:
Socket#10 creation success)
6.3.4 Stage 4
Choose the 3
rd
base unit, RFP3 as Secondary
e) RFP3: Multi cell system = enable and “Save”
f) RFP3: Reboot (Verify Debug log SYNCMGR: This base is ready to join into another Chain”)
g) RFP1, RFP3: Wait 2min for stable Master-Slave chain (SYNCMGR: Socket#10 creation success)
h) RFP3: Check mark ID2/RPN08 and select dropdown “1 – RPN: 04” and “Save”
i) RFP3: Reboot (SYNCMGR: Socket#8 creation success)
Multi-cell chain of 3 base stations has been created successfully. Next step involves adding extensions to
the system.