Parameters
Description
IDx
Repeater unit identity in the chained network.
Permitted Output: Positive Integers
RPN
The Radio Fixed Part Number is an 8-bit DECT cell identity allocated by the
installer. The allocated RPN within the SME must be geographically unique.
Permitted Output: 0 to 255 (DEC) OR 0x00 to 0xFF (HEX)
Name/IPEI
Contains the name and the unique DECT serial number of the repeater. If name is
given the field will be empty.
DECT sync
Source
The “multi cell chain” connection to the specific Base/repeater unit. Maximum
number of chain levels is 12.
Sync. source format: “RPNyy (-zz dBm)”
yy: RPN of source
zz: RSSI level seen from the actual repeater
DECT sync Mode
Manually: User controlled by manually assign “Repeater RPN” and “DECT sync
source RPN”
Local Automatical: Repeater controlled by auto detects best base signal and auto
assign RPN.
Chaining Automatical: Base controlled by auto detects best base or repeater
signal and auto assign RPN. This feature will be supported in a future version
State
Present@unit means connected to unit with RPN yy
FW info
Firmware version
FWU Progress
Possible FWU progress states:
Off: Means sw version is specified to 0 = fwu is off
Initializing: Means FWU is starting and progress is 0%.
X% : FWU ongoing
Verifying X%: FWU writing is done and now verifying before swap
Conn. term. wait” (Repeater): All FWU is complete and is now waiting for
connections to stop before repeater restart.
Complete HS/repeater: FWU complete
Error: Not able to fwu e.g. file not found, file not valid etc