Local Automatical
Repeater controlled by auto detects best base signal and auto assign RPN.
Repeater on base only, repeater on repeater (chain) not supported.
Repeater RPN dynamic assigned in base RPN range.
Chaining Automatical
Base controlled by auto detects best base or repeater signal and auto assign RPN.
Repeater on base or repeater, repeater on repeater (chain) supported.
Repeater RPN static assigned from base.
5. Check “Idx 0
6. Select link “Register Repeater(s) (Base open 5 minutes for repeater registration)
7. Power on repeater placed near base. (default registration mode if production unit)
LED green double flash: Registration mode - if not then press reset button for 4 seconds.
LED green steady: Within a minute the repeater should be registered successful.
LED red steady: Registration timeout, press reset button 4 sec. or power cycle repeater.
To see Repeater signal strength in handset enable “Site survey mode” via hidden menu.
Press key: [MENU] *7378423*
Handset scans and list from left the RPN of base and repeater, below RPN is signal strength in dbm.
Successful registration.