User's Manual

SME VoIP System Guide, Version 1.5
Proprietary and Confidential
Chapter: Multi-cell Setup & Management
92
account
from Base X to Base Y, this phone will de-register from Base X, and register to
Base Y automatically.
Note: Choose Yes when the SIP server supports this feature otherwise choose No
if the Sip server does not support this feature.
Permitted Input: Yes, No
STEP 16 Next, on the MAC-units in chains section, you can manually configure the synchronisation
source tree of the multi-cell system. Multi-cell settings page, scroll to the DECT system settings and
Enable or Disable the “Auto configure DECT sync option source tree” (See description in the table
below). The DECT system RFPI parameter is computed by the system (Its often grayed in a multi-cell
system)
13.4 Summary of Procedure Creating a Chain
We enumerate the short version of how to add 3 base stations units in a multi-cell setup. This can be
applied for up to 40 number of base units. The procedure below is valid ONLY for base station firmware
version 00.36 and above.
This procedure is divided into four (4) main stages. Apply this procedure if all base unit are straight from
production.
13.5 Stage 1
Skip this stage if relevant base stations are already in the network.
a) Add 3 base stations i.e. RFP1, RFP2, RFP3 > Disable the Multi cell system” option and “Save”
b) RFP1, RFP2, RFP3: Reboot from the HTTP SME Configuration Main Page
c) RFP1, RFP2, RFP3: Default by pressing reset button 12-sec.
13.6 Stage 2
Choosing 1
st
base unit i.e. RFP1 as Master
a) RFP1: Define Time server and “Save” from the Time page
b) RFP1: Reboot