User's Manual
SME VoIP System Guide, Version 1.5
Proprietary and Confidential
Chapter: SME VoIP Administration Interface
54
Chain section for details).
Valid Inputs: Enable, Disable
System chain ID
This is an identifier (in string format e.g. 2275) that is unique for a specific multi-
cell system.
Note: There can be several multi-cell systems in SME network. Up to 7 levels of
base stations chains are permitted in a typical setup. Please refer to accompanied
document [2] for further details and description.
Valid Input: 16 bit String length
Synchronization
time (s)
This specifies the period in seconds when elements/nodes (e.g. Base units) in a
specific Multi-cell should synchronise to each other.
Multi cell debug
Enable this feature, if you want the system to catalogue low level multi-cell debug
information or traces.
9.8.2 DECT System Settings
Description of DECT Settings for Specific Base units is as follows:
Parameter
Description
DECT system
RFPI
This is a radio network identity accessed by all Base units in a specific multi-cell
system. It composed of 5 octets. It is actually 5 different variables combined
together.
RFPI Format: XX XX XX XX XX (where XX are HEX values)
Note: Only type e.g. 11 6E 60 49 04 the system reformats as 0x11 0x6E 0x60 0x49
0x04
Access Rights Class (ARC):
Defines network identity structure used by terminals especially in multi-cell
environment. Fixed/default Value=1 (Private multi-cell system).
RFPI: 1X XX XX XX XX
Equipment Installer's code (EIC):
Code that allows terminals to distinguish between separate DECT networks.
Example_RTX_EIC: 0x16E6 (May change in the future)
RFPI: 11 6E 6X XX XX
Fixed Part Number(FPN):
Is a geographically unique identity transmitted to DECT networks to help PP
distinguish between base station communications in different cells/multi-cell
systems.
E.g. FPN: 0x049
RFPI: 11 6E 60 49 XX