RTX Base station Provides RF Channels to Handsets
The base station supports 12 RF channels simultaneously for all DECT bands, summarised below:
The RF communication is provided according to the band standard at the site:
Frequency band: 1880 MHz 1930 MHz (DECT)
1880 1900 MHz (10 carriers) Europe/ETSI
1910 1930 MHz (10 carriers) LATAM
1920 1930 MHz (5 carriers) US
Other frequency bands can be customized via Base station low-level debug programming.
6.2 RTX Base station Mechanics
The base station front end shows an LED indicator that signals different functional states of the base unit
and occasionally of the overall network. The indicator is off when the base unit is not powered.
The table below summarises the various LED states:
LED State
State
Unlit
No power in unit
Unlit/Solid red
Error condition
Blinking green
Initialisation
Solid red
Factory reset warning or long press in BS reset button
Blinking red
Factory setting in progress
Solid green
Ethernet connection available (Normal operation)
Blinking red
Ethernet connect not available OR handset de/registration failed
Solid red
Critical error (can only be identified by RTX Engineers). Symptoms
include no system/SIP debug logs are logged, etc.
Orange
Press reset button of base station.