Datasheet

© 03/2018 | Technical changes without notice. | RTW GmbH & Co.KG | Am Wassermann 25 | 50829 Köln | Fon +49 221. 70 913-0 | Fax +49 221. 70 913-32 | rtw@rtw.com | www.rtw.com14
Timecode Reader
Decoding and display of LTC timecode.
Display: numerical display of LTC (from analog or digital
sources)
Mode: LTC (fi xed), instrument selectable when creating
a Non-Audio group
Input: one analog or digital channel selectable
Colors: selectable, 32 colors
Moving Coil
Display of needle instruments for up to 2-channel Stereo with different
scales.
Type: PPM (L/R), PPM (M/S), VU, Loudness, PPM +
Loudness (L/R; M, S, or I), selectable
PPM:
- Ch. arrangement: Dual, Dual + M/S horizontal, Dual + M/S verti-
cal, Stereo horizontal, Stereo vertical
- Scales: BR IIa: 7. .1, BR IIa ext: 7. .1
BR IIb: +12. .–12 dB, BR IIb ext: +12. .–12 dB
- Integration time: Sample (digital only), 0.1 ms, 1 ms, 10 ms, 20
ms, 150 ms
- Headroom Ref: available with digital sources only: –10 dB;
adjustable from 0 to –20 dB in steps of 1 dB
- S mode: only available, if M/S type is selected: M3, M6
- Peak indicator: Off, Peak, True Peak, BR Peak
- BR Peak Threshold: 6 dB,
BR IIa: adjustable from 4 to 7 dB in steps of
1 dB
BR IIb: adjustable from 0 to 12 dB in steps
of 1 dB
VU:
- Ch. arrangement: Stereo horizontal, Stereo vertical
- Scale analog: VU (–20 to +3 dB)
- Scale digital: VU Digital (–20 to + 3 dB)
- Lead: 0 dB, adjustable from 0 to 12 dB in steps of 1 dB
- Peak indicator: Off, Peak, True Peak
Loudness:
- Ch. arrangement: Dual, Stereo horizontal, Stereo vertical
- Scales: acc. to Loudness settings
- Integration time: acc. to standard
- Peak indicator: Off, no selectable option available
PPM + Loudness:
- Ch. arrangement: Dual-PPM (as described above) with additional
Loudness display (BBC) for M, S, or I (selectab-
le) in one instrument
- Scales: PPM: see above
Loudness: +9 to –9 LU fi xed (mid of scale
corresponds to Target Level)
Numerical display: switchable
Chart
Description: Loudness Chart instrument for displaying and
analyzing the course over time of a loudness
measurement directly on the display.
Loudness Chart Instrument
Functions: Coordinate system displaying a graph with
the course over time of one of the measured
values TP, M, S, or I
Relative Gate view switchable
Adjustable time ranges
Vertical Integrated bargraph switchable
Adjustable tolerance levels
Display: Course over time of the selected value with
color lling or as line
Tolerance Marker
Position of the Relative Gate (doubled hori-
zontal line)
Vertical I bargraph
Colors: Fill: Adoption of the corresponding colors of
the Loudness Sum instrument
Line: cyan (M), light red (S), green (I),
yellow (TP)
Tolerance Marker: coordinate system turns
to light grey except the corridor defi ned by
the tolerance settings
Relative Gate: white
Time range presets: 1 m; 1 m, 5 m, 1 h selectable
Time range select: via preset or onscreen during normal operation
Upper tolerance: as defi ned in the Loudness/Tolerance menu of
each audio group; tolerance above the Target
Level
Lower tolerance: as defi ned in the Loudness/Tolerance menu of
each audio group; tolerance below the Target
Level
Specifi cations (continued)