Datasheet

© 03/2018 | Technical changes without notice. | RTW GmbH & Co.KG | Am Wassermann 25 | 50829 Köln | Fon +49 221. 70 913-0 | Fax +49 221. 70 913-32 | rtw@rtw.com | www.rtw.com12
PPM/True Peak Display
General
Input sources: analog and/or digital
Peakmeter: 2-ch. Stereo to 6-channel (Multichannel, 5.1)
Display: Peak level
Peak hold (selectable color)
Numerical value of the display
Functions: Gain (+20 dB, +40 dB acc. to standard)
Peak hold on/off
Memory
Reset
Analog Peakmeter
Analog scales: DIN5: +5 .. -50 dB,
Nordic: +12 .. -42 dB,
BR IIa: 7 .. 1 (British),
BR IIb: +12 .. -12 dB (British),
Zoom10: +10 .. –10,
Zoom1: +1 .. –1,
SMPTE24: +24 .. –30
SMPTE20: +20 .. –40
NHK
Integration time: acc. to standard or 20 ms, 10 ms, 1 ms, 0,1 ms
Peak hold indicator: 1, 2, 4, 10, 20, 30 s, manual reset or off
Digital Peakmeter
Word width: 24 bit
Digital scales: TP60: +3 .. –60 dB
TP20: +3 .. –20 dB
Dig60: 0 .. –60 dB
Dig20: 0 .. –20 dB
Dig0: +18 .. 0 dB
Dig18: +18 .. –18 dB
Dig40: +20 .. –40 dB
ARD9: +9 .. –60 dB
DIN5: +5 .. -50 dB,
DIN10: +10 .. -50 dB,
Nordic: +12 .. -42 dB,
BR IIa: 7 .. 1 (British),
BR IIb: +12 .. -12 dB (British),
Zoom10: +10 .. –10,
Zoom1: +1 .. –1,
Headroom/Headroom Ref: adjustable in the range from 0 to –20 dB in
steps of 1 dB
Operation fi eld: adjustable in the range from 0 to –20 dB in
steps of 1 dB
Integration time (Attack): acc. to corresponding standard or selectable:
Sample, 20 ms, 10 ms, 1 ms, 0.1 ms
Gain: +20 dB, +40 dB (acc. to standard)
High-pass fi lter: Off, 5 Hz, 10 Hz, 20 Hz
Peak hold indicator: 1 s, 2 s, 4 s, 10 s, 20 s, 30 s, manual reset or off
Over indicator hold time: 1 s or manual
Over indicator PPM
- Threshold: Full Scale, Full Scale -1LSB, Full Scale -2LSB,
–0.1 dBFS, –0.5 dBFS, –1 dBFS, –2 dBFS,
–3 dBFS
- Attack time: 1 to 15 samples
- Word width: 16 to 24 bit, selectable
Over indicator True Peak
- Threshold: adjustable
AES3 Status Monitor
Display: channel data are displayed as plain text, hex
or binary
Channel selectable
Audio bit activity
Hardware status
Global Keyboard
The Global Keyboard is used for control of de-
ned functions in multiple instruments, and for
preset recall. It also allows the external control
with the integrated GP IO interface.
Loudness and SPL Display
EBU R128 Loudness Mode
ITU-R BS.1771 Loudness Mode
ATSC A/85 Loudness Mode
ARIB Loudness Mode
OP-59 Loudness Mode
AGCOM Loudness Mode
CALM Loudness Mode
Specifi cations (continued)