Data Sheet TouchMonitor TM9 Series
TouchMonitor TM9 Series product design award 2011 Modular Software • Touch Screen • I/O Options: Analog, AES3, AES3id, 3G SDI, AoIP • Highly Flexible Screen Layout • 2-ch. PPM/True Peak • Multichannel • Loudness • LRA • Logging • Chart • Timecode • SPL • RTA • SSA • Radar • Premium PPM • BLITS The TouchMonitor TM9 range enters a new level of professional audio metering in terms of precision, performance, efficiency and flexibility.
Hardware Common Configuration • 9“ touch screen 16 : 9 TFT (1024 x 600 pixel) • 16-channel audio interfaces (analog, AES3, AES3id) or 32-channel AoIP interface (for Dante™ or Ravenna/ AES67/ST 2110 networks) - selection required! • 3G SDI interface (option for 16-channel interfaces) • Connectors for Ethernet, VGA, 2 x USB 2.
Hardware (continued) HW20911 HW20912 16-channel audio interface with: • 8-channel analog inputs (electronically balanced, Sub-D) • 8-channel digital inputs and outputs (transformer balanced, 110 Ohm, 4 x AES3 In/Out, Sub-D) 16-channel audio interface with: • 8-channel analog inputs (electronically balanced, Sub-D) • 8-channel digital inputs and outputs (unbal.
Hardware (continued) Preconfigured Models The models are already preconfigured for typical application fields and equipped with a corresponding audio interface. As the previously described devices, they can be expanded with software modules (licences).
Software Standard Software Every TouchMonitor comes with a basic software package. Beside the control functions, this software is able to process the signals of up to 4 routed channels in a maximum count of 4 groups at a time (up to 4 x Mono, 2 x 2-channel Stereo, 1 x 2-channel Stereo and up to 2 x Mono; no 3.1).
Software (continued) SW20008: Timecode Reader SW20013: BLITS Decoding of SDI embedded or LTC timecode. Timecode display. Licence SW20002 is required for the possibility of recalculating loudness. Tool to generate line test signals according to EBU 3304, GLITS and BLITS definition. Automatic and significant analysis of channel allocation, level, phase and delay, and polarity of received BLITS 5.1 test signals.
Dimensions TouchMonitor TM9 20900 Table-Top Unit (20900 + HW2091n, also TM9-Dante, TM9-Video, TM9-Studio, TM9AES16, TM9-BNC) 1 | Front view (dimensions in mm) 2 | Side view (dimensions in mm) 3 | Rear view (dimensions in mm) 8 © 03/2020 | Changes without notice. | RTW GmbH & Co. KG | Am Wassermann 25 | 50829 Köln | Phone +49 221. 70 913-0 | Fax +49 221. 70 913-32 | rtw@rtw.com | www.rtw.
Dimensions (continued) TouchMonitor TM9 20900OEM Version (20900OEM + HW2091n) 1 | Front view (dimensions in mm, tolerance: ±0.2 mm) 2 | Side view (dimensions in mm, tolerance: ±0.5 mm) For adequate ventilation a minimum space is required: min. 10 mm at all sides and min. 100 mm on the rear side! 3 | Rear view (dimensions in mm, tolerance: ±0.5 mm) 4 | Front panel cut-out (dimensions in mm, tolerance: ±0.2 mm) 5 | Vertical mounting orientation © 03/2020 | Changes without notice. | RTW GmbH & Co.
Connection Connectors ATTENTION! - For operating the 20900OEM version an appropriate mains adapter is required. RTW recommends the use of the RTW wide voltage power supply 1178-R (100 - 240 V AC/24 V DC, 2.7 A) approved for TouchMonitor and available as an accessory. For 20900OEM and its combinations with mounting adapters TM9-MA4U, or TM9-MADT, it has to be ordered separately.
Pin Assignment Analog In 1 -8, Analog In 9 - 16 (electr. bal., 25-pin Sub-D-F) Pin: Function: 1 14 2 15 3 16 4 17 5 18 6 19 7 20 8 21 9 22 10 23 11 24 12 25 13 Analog input 8 resp. 16 (+, hot) Analog input 8 resp. 16 (–, cold) Shield/chassis Analog input 7 resp. 15 (+, hot) Analog input 7 resp. 15 (–, cold) Shield/chassis Analog input 6 resp. 14 (+, hot) Analog input 6 resp. 14 (–, cold) Shield/chassis Analog input 5 resp. 13 (+, hot) Analog input 5 resp. 13 (–, cold) Shield/chassis Analog input 4 resp.
Specifications System General Power requirements: Current drain: Power dissipation: Display: Connectors: with HW20911: with HW20912: with HW20913: with HW20914: with HW20915: with HW20917: with HW20918: Dimensions (W x H x D): Weight: Operating temperature: +24 V DC (external 2 A max. overcurrent protective device shall be installed!) Some devices may have a DC input connector marked +12 V DC. These units may be operated with a nominal DC voltage in the range of +12 V to +24 V DC. 1 A nominal, 2.
Specifications (continued) Basic 4-Channel PPM (Standard Software) General Input sources: 4-channel Peakmeter: Display: Functions: Analog Peakmeter Analog scales: Integration time: Peak hold indicator: analog and/or digital, depending on selected audio interface up to 4 x Mono, 2 x Stereo, 1 x Stereo and up to 2 x Mono (no 3.1) • max. of 4 ch. total in max. 4 groups • Peak level • Peak hold • Numerical value of the display • Gain (+20 dB, +40 dB acc.
Specifications (continued) Customer Specific Loudness Mode Display: • Bargraphs for each single channel (can be combined with PPM bargraphs) • M bargraph (Momentary - summation of momentary loudness values of all channels for a short span of time) • S bargraph (Short - loudness summation value of an adjustable dynamic time frame) • I-Bargraph (Integrated - long term loudness value infinite or manual control) • adjustable tolerance range for M, S, I Numerical display: for M, S, I values (labelling adjustable)
Specifications (continued) 45 dB max.
Specifications (continued) Moving Coil Instrument (available in stereo mode only) Type: PPM (L/R), PPM (M/S), VU, Loudness, PPM + Loudness (L/R; M, S, or I), selectable PPM: - Ch. arrangement: Dual, Dual + M/S horizontal, Dual + M/S vertical, Stereo horizontal, Stereo vertical - Scales: • BR IIa: 7. .1, BR IIa ext: 7. .1 • BR IIb: +12. .–12 dB, BR IIb ext: +12. .–12 dB - Integration time: Sample (digital only), 0.
Specifications (continued) Analyzer Functions: Displays: - Course: - State/Alarm: - Report: • Automatic detection and analysis of incoming BLITS test signals Channel related for incoming BLITS test signals Bars for fast and easy recognition of • General signal state • Channel allocation • Level • Phase and Delay • Polarity In cases of error, the bars will be displayed in red Schedule showing values for • incoming channels • channel allocation • measured level in dBFS • detected differences in dB • Phase a
Specifications (continued) Optional Licence SW20015: ISA - Immersive Sound Analyzer Dynamic display for visualizing the interaction of all signal parameters of spatial (immersive) surround formats like 5.1.2, 5.1.4, 7.1.2 or 7.1.4 corresponding to the subjective listening impression across two layers (beds) --- Precondition: Software licences SW20001, SW20002, and SW20004 are activated.
Specifications (continued) Hardware options • Software licence SW20008: Timecode Reader for the display of SDI embedded or LTC timecodes, recalculation --- Precondition: Licence SW20002! --- • 3G-SDI interface HW20930 when placing a new order together with selected audio interface (HW20911 to 20915) or model (not for TM9-RAV or TM9-Dante) • Software licence SW20013: BLITS to use BLITS analyzer and BLITS, GLITS, EBU 3304 line test signals.
Product Line-up 19“/4U Mounting Adapter TM9-MA4U for mounting 20700OEM into standard 19“ environments.