Datasheet

© 03/2020 | Changes without notice. | RTW GmbH & Co. KG | Am Wassermann 25 | 50829 Köln | Phone +49 221. 70 913-0 | Fax +49 221. 70 913-32 | rtw@rtw.com | www.rtw.com 16
Customer Specifi c Loudness Mode
Display: Bargraphs for each single channel
(can be combined with PPM bargraphs)
M bargraph (Momentary - summation of
momentary loudness values of all channels
for a short span of time)
S bargraph (Short - loudness summation
value of an adjustable dynamic time frame)
I-Bargraph (Integrated - long term loudness
value infi nite or manual control)
adjustable tolerance range for M, S, I
Numerical display: for M, S, I values (labelling adjustable)
for LRA, TPmax, Mmax, Smax, I-time values
Scales: Loudness scale:
EBU+9: +9 .. –18 LU
EBU+3: +3 .. –18 LU
EBU+18: +18 .. –36 LU
EBU+9a: 14 .. –41 LUFS
EBU+18a: –5 .. –59 LUFS
EBU0: 0 .. –60 LUFS
ITU+9: +9 .. –18 LU (Loudness Units)
ITU0: 0 .. –30 LKFS
ATSC0: 0 .. –60 LKFS
ATSC0a: 0 .. –30 LKFS
Weighting fi lter: K fi lter acc. to ITU BS.1770
Target Level: –23 LUFS; adjustable in the range from –10
to –30 LUFS in steps of 1 LUFS
–24 LKFS; adjustable in the range from –10
to –30 LKFS in steps of 1 LKFS
Time & Gate Momentary:
- Window Time: adjustable in the range from 200 ms to 1000
ms in steps of 100 ms
- Integration Time: IEC 125 ms Fast, 250 ms (IRT), 500 ms, 750
ms, IEC 1000 ms Slow, 1500 ms, 2000 ms
selectable
Time & Gate Short:
- Integration Time: 3 s; time window adjustable from 1 to 20 s in
steps of 1 s
Time & Gate Integrated:
- Silence Gate: –70,0 LUFS; adjustable in the range from
–80,0 to –40,0 LUFS in steps of 0.5 LUFS,
switchable
–70,0 LKFS; adjustable in the range from
–80,0 to –40,0 LKFS in steps of 0.5 LKFS,
switchable
- Relative Gate: –10,0 LU; adjustable from –40,0 LU to 0 LU in
steps of 0.5 LUFS, switchable
Level adjustment for the
summation: 0.0 dB (L, R, C), adjustable between –3 and
+3 dB in steps of 0.5 dB
+1.5 dB (LS, RS, LSR, RSR), adjustable
between –3 and +3 dB in steps of 0.5 dB
Off (LFE), selectable: Off, 0 dB, 10 dB
Tolerance Levels:
- TP Headroom: –9.0 dB; adjustable from 0 to –20 dB in steps of
0.1 dB
- TP Over Sensitivity: 0.0 dB; adjustable from 0 to –20 dB in steps of
0.1 dB
- M High: +1.0 LU; M tolerance above Target Level adjus-
table from 0 to 10 LU in steps of 0.1 LU
- M Low: –1.0 LU; M tolerance below Target Level adjus-
table from 0 to –12 LU in steps of 0.1 LU
- S High: +1.0 LU; S tolerance above Target Level adjus-
table from 0 to 10 LU in steps of 0.1 LU
- S Low: –1.0 LU; S tolerance below Target Level adjus-
table from 0 to –12 LU in steps of 0.1 LU
Specifi cations (continued)
- I High: +1.0 LU; I tolerance above Target Level adjus-
table from 0 to 10 LU in steps of 0.1 LU
- I Low: –1.0 LU; I tolerance below Target Level adjus-
table from 0 to –12 LU in steps of 0.1 LU
Loudness Test Time Control
Settings for operating automatic, semi-automatic or manual loudness
measurements.
Start:
- Functions: Autostart after preset load, autostart with gate,
autostart with gate and autoreset, manually via
keys or GPI. With Timecode Reader licence
(SW20008) activated additional control via
timecode resp. timecode with recalculation.
- Level for gate: –70,0 LUFS/LKFS; adjustable from –85 to
–10 LUFS/LKFS in steps of 0.5 LUFS/LKFS
Stop:
- Functions: manually via keys or GPI, autostop with gate,
autostop with gate and time. The stop function
is automatically set and fi xed to timecode, if the
start function has been set to a timecode option.
- Level for gate: –70,0 LUFS/LKFS; adjustable from –85 to
–10 LUFS/LKFS in steps of 0.5 LUFS/LKFS
- Time for gate: 1 s; adjustable from 1 to 15 s in steps of 1 s
Loudness Range Instrument (LRA)
Display: Graphical display of the Loudness Range
Mode: selectable: LRA Bar, MagicLRA, MagicLRA + I,
MagicLRA + I + Num
Scale range: selectable: 6 LU, 10 LU, 20 LU, 30 LU
LRA low range: 2 LU; adjustable in the range from 1 to 20 LU in
steps of 1 LU
Comfort zone: 4 LU; adjustable in the range from 1 to 20 LU in
steps of 1 LU
LRA high range: depends on the selected scale range and the
spread of the comfort zone
Colors: selectable for each range
SPL Meter Mode
Display: Bargraphs for each single channel
(can be combined with PPM bargraphs)
Summation bargraph
Reference point: adjustable in the range from 68 dB to 88 dB in
steps of 1 dB
Weighting: Linear, A (Leq(A)), C, CCIR (Leq(M)), k
Integration time: Fast (125 ms), Slow (1 s)
Optional Licence SW20003: RTA - Real Time Analyzer
Spectral distribution display of the frequency range of single channels,
channel pairs or groups. For the display of more than 4 channels software
licence SW20001 is required.
Spectrum Analyzer (RTA)
Input sources: selectable: all channels without LF, all channels,
Front, Rear, L/R, single channels, Stereo pairs,
depending on selected mode
Frequency range: Norm: 20 Hz to 20 kHz,
additional band > 20 kHz switchable
LF: 5 Hz to 5 kHz
Number of bands: 1/3-octave: 31 bands,
lter acc. to IEC 225 class 2
1/6-octave: 61 bands
1/12-octave: 120 bands
Weighting fi lter: Linear; Linear, A, C selectable
Peak hold indicator: 1 s, 2 s, 4 s, 10 s, 20 s, 30 s, manual reset or off