Specifications
80 - RedBoot Procedures DeviceMaster Installation and Configuration Guide: 2000506 Rev. B
Telnet Method
e. Click Send.
10. When the RedBoot> prompt appears (after approximately one minute for the
Bootloader and approximately three minutes for SocketServer), type go.
Note: In a few seconds, the ethernet and PWR LEDs cycle through a light sequence
once and then upgrade is complete.
11. If you updated SocketServer: type, fis list and press Enter at the RedBoot> prompt.
Note: You should see file information for a file called default. If you do not see this file,
repeat the process starting with Step 6
.
12. Reset the DeviceMaster by typing reset at the RedBoot> prompt.
Note: In a few seconds the ethernet and PWR LEDs cycle through a light sequence
once and the update is complete.
13. Start your internet browser and enter the IP address of the DeviceMaster to verify
that the new version of SocketServer loads.
Telnet Method Use the following procedure to update the Bootloader or SocketServer with telnet to the
DeviceMaster.
Note: A TFTP server is required to perform firmware updates using Redboot.
1. Verify that you have the .bin file (Locating Software and Documentation
on Page 10).
2. Open a telnet session, type reset, and close the session.
RedBoot> go
... Erase from 0x05030000-0x050c0000: .........
... Program from 0x00000000-0x00084801 at 0x05060000: ...
... Erase from 0x050f0000-0x05400000: .
... Program from 0x007a0000-0x007b0000 at 0x053f0000: .
CCCCCCRaw load done: 542721 bytes read
Address range: 00000000-00084800, Entry point: 00000000,
xyzModem - CRC mode, 4241(SOH)/0(STX)/0(CAN) packets, 8 tries
RedBoot> fis list
Name FLASH addr Mem addr Length Entry point
FIS_directory 0x053F0000 0x053F0000 0x00010000 0x00000000
default 0x05030000 0x00000000 0x00090000 0x00000000
RedBoot>
RedBoot> reset
. . .Resetting