Specifications
76 - RedBoot Procedures DeviceMaster Installation and Configuration Guide: 2000506 Rev. B
Establishing a Telnet Connection
7. Go to the appropriate task:
• Determining the Network Settings
on Page 77
• Configuring the Network Settings on Page 77
• Determining the Bootloader Version on Page 78
• Resetting the DeviceMaster on Page 78
• Uploading Firmware on Page 79
• Configuring Passwords on Page 82
• Redboot Command Overview on Page 83.
Establishing a Telnet
Connection
Use the following procedure to telnet to the DeviceMaster.
1. Open a telnet session, enter the DeviceMaster IP address. If using Windows, open a
Command window and type telnet [ip_address].
Note: Press the Enter key if you have not programmed a password or use the
password previously configured. The DeviceMaster does not come pre-
programmed with a password.
2. Type reset, and close the session.
3. Open a new telnet session, enter the DeviceMaster IP address, and the password.
4. Type dis to disable the Bootloader.
5. Verify that the system responds with a Loading disabled message.
6. Go to the appropriate task:
• Determining the Network Settings
on Page 77
• Configuring the Network Settings on Page 77
• Determining the Bootloader Version on Page 78
• Resetting the DeviceMaster on Page 78
• Uploading Firmware on Page 79
• Configuring Passwords on Page 82
• Redboot Command Overview on Page 83.
*********************************************
**
** Comtrol DeviceMaster Bootloader Version 3.05
** RedBoot(tm) environment - built 08:13:02, Apr 4 2008
** Platform: Comtrol DeviceMaster (ARM 7TDMI)
** Portions Copyright (C) 2000. Red Hat, Inc.
** Portions Copyright (C) 2001-2008 Comtrol Corp.
*********************************************
FLASH: 64 blocks of 65536 bytes each
FLASH: 4194304 bytes (0x05000000 - 0x05400000)
RAM: 8126464 bytes (0x00000000 - 0x007c0000)
RedBoot> dis
Loading disabled
RedBoot> _