Specifications

DeviceMaster Installation and Configuration Guide: 2000506 Rev. B Hardware Installation - 25
4-Port and 8-Port Models
5. Verify that the PWR LED has completed the boot cycle and network connection for
the DeviceMaster is functioning properly using the table below.
6. Go to Initial Configuration
on Page 33 for default network settings and how to
configure the DeviceMaster for use.
4-Port and 8-Port LED Descriptions
PWR
LED on the front panel of the DeviceMaster is lit, indicating you have power
and it has completed the boot cycle.
Note: The PWR LED flashes while booting and it takes approximately 15
seconds for the Bootloader to complete the cycle. When the
Bootloader completes the cycle, the LED has a solid, steady light that
blinks approximately every 10 seconds.
LNK
ACT
The red LNK ACT LED is lit, indicating that
you have a working Ethernet connection.
COL
If the red COL LED is lit, there is a network
collision.
100
If the red 100 LED is lit, it indicates a working
100 MB Ethernet connection (100 MB
network, only). If the LED is not lit, it indicates
a 10 MB Ethernet connection.
Note: For additional LED information, go to the PWR LED table on Page 97.
LNK
ACT
COL
100
10/100 NETWORK
UP DOWN