Specifications

DeviceMaster Installation and Configuration Guide: 2000506 Rev. B Hardware Installation - 21
2-Port (Serial Terminal) 1E/2E Models
Do not connect RS-422/485 devices until the appropriate port interface type has
been configured. The default port setting is RS-232.
5. Verify that the Status LED has completed the boot cycle and network connection for
the DeviceMaster is functioning properly using the following table.
6. Go to Initial Configuration
on Page 33 for default network settings and how to
configure the DeviceMaster for use.
Caution
2-Port LED Descriptions
STATUS
The STATUS LED on the device is lit, indicating you have power and it
has completed the boot cycle.
Note: The STATUS LED flashes while booting and it takes approximately
15 seconds for the Bootloader to complete the cycle. When the
Bootloader completes the cycle, the LED has a solid, steady light
that blinks approximately every 10 seconds.
LINK If the LINK (green) LED is lit, it indicates a working Ethernet connection.
ACT If the ACT (yellow) LED flashes, it indicates network activity.
Note: For additional LED information, go to the STATUS LED table on Page 97.