User manual
21
8. At the prompt, type dbgcmd to access the debug command screens.
9. Press Enter.
An MXP prompt appears.
10. At the MXP prompt, type set rvon ip_addr 10.3.210.12 (this IP Address is for example purposes only).
11. Press Enter.
The IP Address is set for the RVON-I/O.
12. Set the Netmask.
13. At the MXP prompt, type Activate.
RVON-I/O will reset itself to the new IP Address. The current telnet session becomes invalid.
Configure the IP Address Using the Serial Debug Port
NOTE: In order to use the Serial Debug Port to set the IP Address for your RVON-I/O, you must know the intended IP
Address. Also, you must make sure DIP switch 2 is not enabled (CLOSED).
The following instructions will show you how to access the Serial Debug Port screens and show you how to configure the IP
Address for the RVON-I/O
To configure the IP Address for the RVON-I/O, do the following:
1. Connect the PC’s COM port to the RVON-I/O’s serial connector.
2. Run a HyperTerminal program.
The window provided Hyper Terminal is located at Start Programs>Accessories>Communications >HyperTerminal.
3. At the prompt, type dbgcmd.
Figure 5.