User`s manual

30
Auxiliary Power, CN3
The power supply can be conveyed to the module either through the PC/104 bus (J6 and J7) or
through the Auxiliary Power connector, CN3.
Facing the connector pins, the pinout of the Auxiliary Power connector is:
Power Supply Protection
The cpuModule has protection circuitry which helps prevent damage due to problems with the +5V
supply, such as:
Reversed polarity
Overvoltage
Overcurrent
The circuitry includes a user-replaceable fuse, which is located near the PC/104 bus connector. This
fuse is a:
2 amp Nano fuse
Littelfuse part number R451 002
WARNING! If you improperly connect power, the module will almost certainly be
destroyed. Please verify power connections to the module before
applying power.
7 5 3 1
GND -5V GND
+5V -12V +12V +5V
8 6 4 2
NOTE!
-5VDC, +12VDC and -12VDC voltages are not used by the module,
but are carried on the PC/104 bus connectors.