Installation manual
101.6
177
135
482
465
401
177
135
S-1608/S-0816 Specifications
Number of Channels
AD and DA Conversion
Frequency Response
Total Harmonic Distortion + Noise
Dynamic Range
Cross Talk
Nominal Input Level
PAD
Input Impedance
Nominal Output Level
Output Impedance
Recommended Load Impedance
Residual Noise Level (IHF-A, typ.)
Equivalent Input Noise Level
Network Latency
Connectors
Indicators
Power Supply
Power Comsumption
Phantom Power
Dimensions
Weight
Operation Temperature
Accessories
+48 V / 14 mA (each input, remote controlled)
401 (W) x 135 (D) x 177 (H) mm or
15-13/16 (W) x 5-3/8 (D) x 7 (H) inches
5.5 kg 12 lbs 3 oz
0 to +40 degrees Celsius
+32 to +104 degrees Fahrenheit
Power Cord x 1, REAC Connector Cover x 1, Ferrite Cores x 1
Rubber Foot x 4, Rack Mount Kit x 1, Owner's Manual
S-1608 : 16 in 8 out S-0816 : 8 in 16 out
24 bit / 96 kHz
-2 dB / +0 dB (@ +4 dBu, 20 Hz to 20 kHz)
0.05 % or less (Pad: On, Input Gain: +4 dBu, 22Hz to 20 kHz)
110 dB
-80 dB or less (Input Gain: +4 dBu, typ.)
-65 to -10 dBu (PAD: Off), -45 to +10 dBu (PAD: On)
(1 dB step, Max. +28 dBu)
20 dB On/Off
14 k ohms
+4 dBu, Max. +22 dBu
600 ohms
10 k ohms or greater
-80 dBu or less
S-1608: -128 dB S-0816: -124dB
375 microseconds when using REAC cable only (*1)
(AD>REAC>DA Latency: approx 1.2 ms)
S-1608 : Analog Input x 16 (XLR type, balanced, phantom power)
Analog Output x 8 (XLR type, balanced)
Digital Output connector x 1 (Optical type)
REAC Connector x 1 (RJ-45 EtherCon type)
Remote Connector x 1 (RS-232C, DB-9 type)
S-0816 : Analog Input x 8 (XLR type, balanced, phantom power)
Analog Output x 16 (XLR type, balanced)
Digital Output connector x 1 (Optical type)
REAC Connector x 1 (RJ-45 EtherCon type)
Remote Connector x 1 (RS-232C, DB-9 type)
POWER Indicator x 1, REAC Indicator x 1,
REMOTE Indicator x 1, MUTE ALL OUTPUTS Indicator x 1
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
45W
*1: When a REAC Splitter S-4000-SP or a switching hub is used in-line with REAC cables, the network latency will increase by the
amount of processing delay introduced by the splitting device itself. The actual delay is dependant upon the specifications of the
splitting device.
* 0 dBu = 0.775 Vrms
440
434.6
482
465
336265.4
57.176.257.1
266.4
440
434.6
365.8
386.7
482
465
132.5
57
133.8
Accessories
32 in 8 out
Sample Rate: 96.0 kHz
Signal Processing: 24 bit
-2 dB / +0 dB (@ +4 dBu, 20 Hz to 20 kHz)
110 dB
-80 dB
0.05 % or less
(Pad: On, Input Gain: +4 dBu, 22 to 20000 Hz)
-65 to -10 dBu (PAD: Off) -45 to +10 dBu (PAD: On)
(1 dB step, Max. +28 dBu)
Number of Channels
AD Conversion
DA Conversion
Frequency Response
Total Harmonic
Distortion + Noise
Dynamic Range
Cross Talk
PAD
Input Impedance
Nominal Output Level
Output Impedance
Network Latency
Equivalent Input
Noise Level (E.I.N.)
Residual Noise Level
(IHF-A, typ.)
Recommended Load
Impedance
20 dB On/Off
20 k ohms
+4 dBu, Max. +22 dBu
150 ohms
375 microseconds when using REAC cable only
(AD - REAC - DA Latency: about 1.2 ms)
-128 dB
-90 dBu
10 k ohms or greater
Number of Channels
Connectors
8 in 32 out
Frequency Response
AD Conversion
DA Conversion
-2 dB / +0 dB (@ +4 dBu, 20 Hz to 20 kHz)
Sample Rate: 96.0 kHz
Signal Processing: 24 bit
Sample Rate: 96.0 kHz
Signal Processing: 24 bit
Dynamic Range
Cross Talk
Nominal Input Level
Input Impedance
Nominal Output Level
Output Impedance
Recommended Load
Impedance
Residual Noise Level
(IHF-A, typ.)
Network Latency
Total Harmonic
Distortion + Noise
110 dB
-80 dB
+4 dBu, Max. +22 dBu
30 k ohms
+4 dBu, Max. +22 dBu
600 ohms
375 microseconds when using REAC cable only
(AD - REAC - DA Latency: about 1.2 ms)
10 k ohms or greater
-90 dBu
0.05 % or less (Input Gain: +4 dBu, 22 to 20000 Hz)
Input: 1 (DB-25 type, balanced, 8 channels)
Output: 4 (DB-25 type, balanced, 32 channels each)
REAC: MAIN, BACKUP (RJ-45 EtherCon type)
Remote Connector: 1 (RS-232C, DB-9 type)
MIDI Connectors: IN, OUT (5-pin DIN type)
Indicators
AC Power Supply
DC Power Supply
Power Consumption
Dimensions
Accessories
Operation Temperature
Weight
(for an optional external
power supply unit;
Model S-240P)
Current Draw
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
+24 V (from optional external power supply unit : S-240P):
70 W
Power Cord, REAC Connector Covers, Ferrite Cores,
Connector Guard, Screws for Connector Guard
Installation Manual
0 to +40 degrees Celsius
+32 to +104 degrees Fahrenheit
9.4 kg, 20 lbs 12 oz
482.0 (W) x 386.7 (D) x 133.0 (H) mm
19 (W) x 15-1/4 (D) x 5-1/4 (H) inches
6 A
Nominal Input Level
Sample Rate: 96.0 kHz
Signal Processing: 24 bit
Connectors
Indicator
EXT Indicator (External Power Supply Unit)
INT Indicator
REAC Indicator
CTRL Indicator
ALARM Indicator
MUTE ALL OUTPUTS Indicator
Power Cord, REAC cable (10 m, Cat5e crossover cable)
Adhesive-backed number label sheets, REAC Connector Covers
Ferrite Cores, Owner's Manual
AC Power Supply
DC Power Supply
Power Consumption
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
+24 V (from optional external power supply unit : S-240P):
130 W
Phantom Power
Dimensions
+48 V / 14 mA (each input on SI-AD4, remote controlled)
482.0 (W) x 336.0 (D) x 266.4 (H) mm
19 (W) x 13-1/4 (D) x 10-1/2 (H) inches
Weight
Operation Temperature
17.0 kg, 37 lbs 8 oz
0 to +40 degrees Celsius +32 to +104 degrees Fahrenheit
6 A
Input: 32 (XLR type, balanced, phantom power, 4 ch input module x 8)
Output: 8 (XLR type, balanced, 4 ch output module x 2)
REAC: MAIN, BACKUP (RJ-45 EtherCon type)
Remote Connector: 1 (RS-232C, DB-9 type)
MIDI Connectors: IN, OUT (5-pin DIN type)
Current Draw
(for an optional external
power supply unit;
Model S-240P)
EXT Indicator (External Power Supply Unit)
INT Indicator
REAC Indicator
CTRL Indicator
ALARM Indicator
MUTE ALL OUTPUTS Indicator
* 0 dBu = 0.775 Vrms
* 0 dBu = 0.775 Vrms
S-4000S-3208 40CH I/O Modular Rack
S-4000S-3208
S-4000H 8x32 FOH Unit
S-4000H
S-1608/S-0816
S-1608/S-0816
S-1608/S-0816 with rack mount kit
6
0.9
5
4
.3
89.2
54.6
215
87.8
414.3
406.4
482
465
440
434.6
89.1
465
482
204.9
340
87.8
76.2
224.8
43.8
32
Connector
Indicators
Power Supply
Dimensions
Weight
Operatin Temperature
Accessories
Remote Connector: 1 (RS-232C, DB-9 type)
Supplied from connected device. (S-4000S, S-4000H; through the remote cable)
215.0 (W) x 87.0 (D) x 54.6 (H) mm, 8-1/2 (W) x 3-7/16 (D) x 2-3/16 (H) inches
0.8 kg, 1 lb 13 oz
0 to +40 degrees celsius, +32 to +104 degrees Fahrenheit
Remote Cable (3 m), Rack Mount Brackets, Installation Manual
CLIP Indicators, SIG Indicators, POWER Indicator, REAC Indicator, CTRL Indicator, Level Meter
Connectors
Indicators
Power Supply
Power Consumption
Dimensions
Weight
Operation Temperature
Accessories
MAIN REAC (RJ-45 EtherCon type) x 5 BACKUP REAC (RJ-45 EtherCon type) x 5
MAIN LNK/ACT Indicator: Green x 5, Orange x 5
BACKUP LNK/ACT Indicator: Green x 5, Orange x 5
POWER A Indicator x 1, POWER B Indicator x 1
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
13 W
482.0 (W) x 224.8 (D) x 43.8 (H) mm or 19 (W) x 8-7/8 (D) x 1-3/4 (H) inches
2.8 kg or 6 lbs 3 oz
0 to +40 degrees Celsius or +32 to +104 degrees Fahrenheit
Power Cord x 2, REAC Connector Cover x 10, Rubber Foot x 4, Owner's Manual
Connectors
Indicators
Power Supply
Power Output
Power Consumption
Dimensions
Weight
Operation Temperature
Accessories
AC Input and DC Output
POWER and ALARM (front panel)
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
+24V / 6A DC
180 W
482 (W) x 340 (D) x 89 (H) mm or 19 (W) x 13-7/16 (D) x 3-9/16 (H) inches
5.4 kg or 11 lbs 15 oz
0 to +40 degrees Celsius or +32 to +104 degrees Fahrenheit
Power Cord, Owner's Manual
Connectors OPTICAL Port(Dual LC, OpticalCon type) x 1, REAC Port (RJ-45, EtherCon type) x 1, POWER LINK Port (mini-DIN 8pin type) x 1
Indicators REAC ACTIVE Indicator: Green x 1, REAC CONNECTION Indicator: Green x 1, OPTICAL ACTIVE Indicator: Orange x 1, OPTICAL
CONNECTION Indicator: Orange x 1, POWER EXT Indicator: Blue x 1, POWER INT Indicator: Blue x 1
Power Supply AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
Power Consumption 10 W
Dimensions 218.0 (W) x 239.9 (D) x 46.3 (H) mm, 8-5/8 (W) x 9-1/2 (D) x 1-7/8 (H) inches
Weight 1.3kg, 2 lbs 14 oz
Operation Temperature 0 to +40 degrees centigrade, +32 to +104 degrees Fahrenheit
Accessories Power Cord x 1, REAC Cable (5m) x 1, REAC Connector Cover x 1, Rubber Foot x 4, Screw Set x 1, Owner’s Manual
Options REAC Cable(100m): SC-W100S, POWER LINK Cable: ARC-15 (AR-LINK CABLE), Rack Mount Adaptor: RAD-50
S-OPT REAC Optical Converter Unit
S-4000-SP REAC Splitter
S-4000R Remote Control Unit
S-4000R
S-4000-SP
S-240P
S-240P External Power Supply Unit
S-OPT
REAC Optical Converter Unit
The S-OPT unit converts REAC signals to
and from optical signals for long distance
digital audio transmission
(up to 2km or 1.2 miles).
S-4000R
Remote Controller
S-4000R can be used with both the S-4000S
and S-1608 snake systems. It provides easy
remote control of gain adjustments and controls
Phantom power and PAD Settings. The
S-4000R can save up to 10 setups to internal
memory for instant recall of the all settings.
S-4000-SP
REAC Splitter
The S-4000SP is a dual 5-port dedicated gigabit splitter for the RSS Digital Snake System
that provides the highest level of reliability with backup REAC ports, two power supplies and
Neutrick(R) Ethercon Connectors.
W100S-R
100 meter REAC Cable and Reel
Reel-mounted crossover
cable with Neutrik(R)
Ethercon connectors
S-4000 RCS
Remote Control Software
As an alternative to the S-4000R a
computer can be connected to the
REMOTE terminals (RS-232C) of
any snake system and controlled by
the S-4000 RCS Remote Control
Software. This software is available
as a free download for Mac or PC.
S-240P
External Power Supply Unit
Supplies redundant DC power
to an S-4000S or S-4000H.
Outputs DC24V 6A power.
SC-W100S
100 meter Cat5e cable
Crossover cable with
Neutrick (R) Ethercon connectors
Analog Breakout cables for connecting an S-4000H with a mixing console
SC-A0805DMSC-A0805DF
25 pin D-Sub
Female XLR (x8) cable x1
Length : 4.5 meters
25 pin D-Sub
Male XLR (x8) cable x4
Length : 4.5 meters
Optional Items
1
EDIROL Video Equipment
10
RSS Digital Snake Systems
11
EDIROL Video Equipment
11
RSS Digital Snake Systems