Specifications

I/O units and peripheral equipment
【I/O modular rack】
S-4000S-3208
32 in/8 out for stage use. All inputs have remote preamp/
PAD/phantom power. 24-bit/96kHz AD/DA converters.
Audio transmission and power supply redundancy.
【I/O modular rack】
S-4000S-0832
8 in/32 out for FOH I/O unit which is the companion to the
S-4000S-3208. All the specifications are the same as the
S-4000S-3208, except for the inverted I/O.
【FOH unit】
S-4000H
8 in/32 out FOH I/O unit that uses D-Sub connectors.
Specs including the AD/DA converters are the same as the
S-4000S-0832, but without preamps.
【I/O modular rack】
S-4000S-MR
This rack can be customized in blocks of 8 channels when
combined with the modules from the SI/SO series, which have
both analog and digital I/O. Audio transmission and power
supply redundancy is possible.
【Stage unit】
S-1608
16 in/8 out multi-box type stage unit. All inputs have
remote preamp/PAD/phantom power. 24-bit/96kHz AD/DA
converters.
【FOH unit】
S-0816
8 in/16 out multi-box type stage unit. All inputs have
remote preamp/PAD/phantom power. 24-bit/96kHz AD/DA
converters.
【Remote controller】
S-4000R
Remote controller to control the built-in preamps in the I/O
units. Provides gain control setting for each channel and ON/
OFF switching of PAD and phantom power. Up to ten setups
can be stored in the on-board memory.
【Analog modules for S-4000S-MR】
SI-AD4
SO-DA4
4ch analog input module
4ch analog output module
【Digital modules for S-4000S-MR】
SI-AES4
SO-AES4
4ch AES/EBU input module.
Supports 96/48/44.1kHz
4ch AES/EBU output module.
Supports 96/48/44.1kHz
with clocking options.
【Remote control software】
S-4000RCS
Remote control software for the S-4000 and S-1608 systems,
providing the same functionality as the S-4000R. Free
download available from the Roland Systems Group website.
【Splitter】
S-4000-SP
REAC splitter to split and extend the network. It has five
main and five backup ports supporting audio transmission
redundancy. Ethercon design with separate independent power
supplies for main and back-up ports.
【Optical converter】
S-OPT
Converter for transmitting REAC through optical cable.
Maximum transmittable distance is 2km. Uses Neutrik®
OpticalCon Dual LC optical connectors allowing you to
connect standard optical cables.
【Redundant External power supply unit】
S-240P
Power supply unit for the S-4000S and S-4000H. Connects to
the DC socket of each I/O modular rack. By using AC power,
you can achieve power source redundancy.
【REAC cable】
W100S-R
Crossover CAT5e cable. Uses
Neutrik® EtherCon connectors.
The W100S-R is a reel-mounted
100 meter cable. The SC-W100S
is the same length without a
reel. The SC-W20F is a 20 meter
premium "lay-flat" cable.
SC-W100S SC-W20F
【Analog multi-cables】
SC-A41C
These multi-cables are
convenient for connection
to the S-4000H, analog
consoles, and other
equipment. The SC-
A0805DF has eight female
XLR connectors and a 25-
pin D-Sub connector. The
SC-A0805DM has eight
male XLR connectors and
a 25-pin D-Sub connector.
Each cable is 4.5 meters
long.
Configurable up to 40 input and 40 output
channels
SC-A0805DM
SC-A0805DF
5