Installation Manual

19
INSTALLATION MANUAL
4. FEA
TURES GUIDE
XTO-IP Alarm panel
Enter a new end user Badge/Code Delete an end user Badge/Code
ENTER A
BADGE/CODE
Press twice on the right
arrow
DELETING
BADGES/CODES
Badges/codes list
Select badge/code
then
OK or YES
DELETING CODE
ACCESS 5
CODE
DELETED
BADGE OR CODE
CODE NAME :
CONFIRM THE
CODE
ACCESS 2
ENTRY COMPLETE
BADGES
ACCESS CODES
ENTER A
BADGE/CODE
Enter a 4-6 digit user code and
OK or YES
or present a badge in front of the reader until
you hear the registration beep.
OK or YES
OK or YES
OK or YES
OK or YES OK or YES
OK or YES
When a code is created (1000 for example),
the 2 next codes and previous codes (0998,
0999, 1001 and 1002) will be automatically
reserved.
The +1 code (1001) is used for disarming
under duress.
The +2 code (1002) is used for panic.
The -1 and -2 codes (0998 et 0999) are
reserved to prevent conflicts when creating a
new user code.
Reserved Codes
000000
From 9998 to 9999
From 99998 to 99999
From 999898 to 999999
From 314157 to 314159
All user codes +1
All user codes +2
All user codes -1
All user codes -2
Reserved Codes
Up to 19 codes (or badges) can be registered
into the panel with the engineer code.
A code has 4 to 6 digits (0 to 9).
The table presents the reserved code
possibilities that cannot be used.
Those codes are used for maintenance or as
panic/duress codes.
A total of 186 codes are forbidden.