INSTALLATION MANUAL XTO / XTO-IP ALARM PANEL SERIES DOC. - REF. 230-XTO-IP MODIF. DATE : SEPTEMBER 2018 FIRMWARE VERSION : XLP.04.04.00.
INSTALLATION MANUAL INTRODUCTION Description The XTO / XTO-iP is a fully wireless alarm system. It is powered by standalone Lithium batteries. This panel has been designed for outdoor installations, with its weatherproof casing and extended operating temperature range. With the Motion Viewers™ and Videofied® range of products, the XTO-iP panel provides video verification in case of intrusion. Technology The XTO-iP alarm panel, like all Videofied devices, uses the S2View® patented technology.
INSTALLATION MANUAL SUMMARY Introduc tion............................................................................................................2 Summar y..................................................................................................................3 1.Panel setup.........................................................................................................................4 1.1 SIM card installation..........................................................................
1. PANEL SETUP INSTALLATION MANUAL 1.1 SIM card installation Before removing the front cover from its box, Put the SIM card on the plastic base (Take care to respect the right direction). DO NOT insert or remove the SIM card while the panel is powered. 1.2 Panel bracket mounting The four screwholes here opposite are intended to mount the bracket, the latter beeing used to attach the panel to the wall or a pole. Mounting the panel is not required for programming.
1. PANEL SETUP INSTALLATION MANUAL 1.3 Powering and initialization • The panel is powered either with 4 LSH20 Lithium batteries or mains powered with 4 alkaline backup batteries. • Always replace all 4 batteries at once. Mixing new and used batteries can severely damage the panel (risk of explosion). • Press and hold the PROGRAMMING BUTTON for 10 seconds, until the indicator LED blinks twice. • The panel is now reset, a CMA, XMA or XMB has to be enrolled to configure the panel.
1. PANEL SETUP INSTALLATION MANUAL 1.4 Pairing the remote keypad • Press the XTO programming button and release for the enrollment of a programming keypad. • Insert all LS14500 Lithium batteries into the keypad. • Do not mount the keypad. It will display one of the following screens: RSI (c) 2013 videofied.com or <=========XX=========> • Press on both CLR and ESC NO keys at the same time and release. The indicator LED on the keypad will blink rapidly. Wait for the keypad to pair.
INSTALLATION MANUAL 2. XTENDER MODE The panel can be used as standard standalone alarm system but it can also be connected to an existing alarm system capable of latching a 9-12Vcc* voltage used for its arming/disarming. 2.1 Standalone Mode In this functioning mode, the XTO-iP panel works as a standard hybrid alarm system with 25 wireless peripherals and 3 programmable inputs. It is a totally standalone alarm system. 2.
INSTALLATION MANUAL Keypad Display 3. XTO-IP PANEL PROGRAMMING Actions and comments KEYPAD 1 RECORDED OK or YES < - LANGUAGE : - > ENGLISH (UK) for language selection The system can also be programmed in : french, italian, german, dutch, spanish, swedish, portuguese, danish, czech and polish. The language can be changed at any time once the panel is programmed in the MAINTENANCE menu.
3. XTO-IP PANEL PROGRAMMING INSTALLATION MANUAL Keypad display Actions and comments You may name the installer code using the Alphanumeric Keypad. CODE NAME : If using automatic setting (called installer default list), enter the name of the list. OK or YES Warning : If the wrong installers list name is used it cannot be set later, the system must be defaulted. ACCESS 1 REGISTERED Leaving the name blank by pressing ESC NO, it will be named ‘ACCESS 1’ by default.
3. XTO-IP PANEL PROGRAMMING INSTALLATION MANUAL Keypad display Actions and comments PERIODIC TEST Test Periodicity: 1 hour, 12 hours, 24 hours, 48 hours, 7 days or no tests. PERIODIC TEST : 24 HOURS We suggest a 24 hours periodic test call. To select periodicity OK or YES TEST (hour) : 04: OK or YES TEST (minutes) : 04:15 OK or YES CODE/STATE MODIFICATION? OK or YES CODE/STATE MODIFICATION ESC NO ALARM: event transmitted upon occurrence.
INSTALLATION MANUAL IP1 ADDRESS 0.0.0.0 ESC NO SERVER ADDRESSES ? ESC NO STRATEGY: ETH+2G3G4G 3. XTO-IP PANEL PROGRAMMING DOMAIN NAME 1 PORT 1 888 The IP1 address, Domain name 1 and/or Port 1 are provided by the monitoring station. Leave Port details at 888 unless otherwise instructed. Press OK or YES to enter/modify the parameter then OK or YES for validation.
3. XTO-IP PANEL PROGRAMMING INSTALLATION MANUAL ETHERNET parameters configuration IP PARAMETERS ? OK or YES DHCP : ENABLED DHCP : DISABLED OK or YES If the router forces a static IP address for the panel, there will then be a need to define DHCP as DISABLED. You will then need to fill in the following network parameters fields : Panel IP, IP Mask, Primary DNS, Gateway and Secondary DNS.
3. XTO-IP PANEL PROGRAMMING INSTALLATION MANUAL For full compatibility with EN50131, press OK or YES. COMPATIBILITY EN 50131 NORMS ? Otherwise, press ESC NO. ESC NO OK or YES Press ESC NO to default the area names. AREAS CONFIGURATION Enter the name of the area 1 and OK or YES. Repeat the procedure for areas 2,3 and 4. For further details, please refer to chapter 4.3.
INSTALLATION MANUAL 3. XTO-IP PANEL PROGRAMMING XTENDER mode configuration ARMING PROFILE : FROM THE HOST OK or YES MODE SLOW : The panel will arm each device one at a time saving battery life. We recommend this mode. ARMING MODE MODE : SLOW MODE : FAST MODE FAST : The panel will arm all devices at the same time. This mode increases significantly the battery consumption. OK or YES to choose the parameter.
3. XTO-IP PANEL PROGRAMMING INSTALLATION MANUAL Each device has a unique programming button or a specific manipulation. Please refer to the Installation Sheet for the device you would like to program. RECORDING DEVICES PRESS PROGRAM BUTTON OF DEVICE Please check the radio level of each device on its final location. The result must be 8 out of 9 as a minimum (Please refer to the Radio Range section, page 8 for further details).
4. FEATURES GUIDE INSTALLATION MANUAL 4.1 Get to Access level 4 Tue 29/10 DISARMED 11:23 LVL:1 ACCESS LEVEL 1 ACCESS LEVEL LEVEL : 1 OK or YES To unlock and get access to the installer level 4, you need to successively enter TWO codes (in any order) : • INSTALLER CODE (entered during intial programming). • USER CODE (Level3): the user must authorize the installer to get access to the configuration of his panel. ACCESS LEVEL LEVEL : 4 OK or YES BADGE OR CODE OK or YES 4.
4. FEATURES GUIDE INSTALLATION MANUAL 4.3 Arming and Siren Mode Configuration • Use the to go to menu : CONFIGURATION (LEVEL 4) > SPECIAL ARMING MODES > FULL ARM, SP1 or SP2 use direction arrows to select the arming mode you want to modify and OK / YES. • There are 3 different arming modes : FULL ARM : Arming of all areas and all devices. Use a badge or a user code and press OK / on the XMA/XMB keypad or the YES key on the CMA keypad.
4. FEATURES GUIDE INSTALLATION MANUAL 4.4 Manage badges and access codes Access Level Access Level Definition & Rights LVL 1 Standby Level LVL 2 Restricted USER level, where it is only possible to arm/disarm the system. USER level, where it is possible to arm/disarm the system, check the event log, test the devices. LVL 3 Modifications of the settings are not possible at this level. User Level 3 can create Level 2 or Level 3 access codes or badges.
4. FEATURES GUIDE INSTALLATION MANUAL Enter a new end user Badge/Code Delete an end user Badge/Code ENTER A BADGE/CODE BADGES ACCESS CODES Press twice on the right arrow OK or YES ENTER A BADGE/CODE DELETING BADGES/CODES OK or YES OK or YES BADGE OR CODE Badges/codes list Enter a 4-6 digit user code and Select badge/code then OK or YES OK or YES or present a badge in front of the reader until you hear the registration beep.
4. FEATURES GUIDE INSTALLATION MANUAL 4.
4. FEATURES GUIDE INSTALLATION MANUAL EVENT LOG 4.6 Read the event log When user disarms the system, the keypad indicates the last event. In case of the user needs to read the full log file, use the keypad to go in EVENT LOG, press OK or YES on SELECT LAST EVENTS and use arrow to list the events. OK or YES SELECT LAST EVENTS OK or YES 15/10/13 11:29 MODIFIED PARAMET 15/10/13 11:10 SYSTEM DISARMED Press OK or YES for more information about an event 4.
INSTALLATION MANUAL 4. FEATURES GUIDE 4.8 Golden rules 1 Area 1 is always delayed.When you register a keypad or a badge reader into an area, that area will automatically be delayed. 2 Never position a panel next to a high voltage electrical cabinet . 3 Press CLR to erase a typing mistake. 4 Never register the same device twice (delete from the system first). 5 Registration of up to 25 devices (including the keypad). 6 Respect indoor infrared devices installation height (2m10 to 2m30).
5. TRANSMITTED EVENTS LIST INSTALLATION MANUAL The XTO-iP panel can be configured to enable or disable the transmission of events like alarms or defaults. The installer can modify the default sending settings for those events, although it will end the EN50131 standard compliance. These are the default transmitted events : DEVICE (intrusions) ALERT (Panic Buttons) PANEL LOW BATT. TAMPER DEVICE LOW BATT. PERIODIC TEST DURESS CODE FIRE MEDICAL ASSIST.
6. 2G3G4G ERROR CODES INSTALLATION MANUAL IMPORTANT: The PIN of the SIM card has to be deactivated or 00000. The following is a list of error codes that can appear after the 2G3G4G test. In case of 2G3G4G (GPRS) errors during initial programming, we strongly suggest to continue with the installation and perform the 2G3G4G (GPRS) level test again once achieved. 2G3G4G LEVEL : ERROR XXX This error checklist is provided for information purposes only.
INSTALLATION MANUAL 7. TECHNICAL SPECIFICATIONS AND SECURITY NOTES FCC Regulatory Information for USA and CANADA FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
7. TECHNICAL SPECIFICATIONS AND SECURITY NOTES INSTALLATION MANUAL ELECTRICAL DATA TRANSMISSION Communicator Power requirements (option 1) Power supply Type B 9-12 V / 1.2 A Low voltage limit 2G & LAN Ethernet (XTO-iP 210) 3G & LAN Ethernet (XTO-iP 730 830) Communicator type 5.15 V Backup 6V with 4 x 1,5 V D Alkaline batteries /LR20 Low battery limit 4.2 V Battery life (average) 1 year Average current consumption (over 1h) 450µA Max current 1.
INSTALLATION MANUAL 7. TECHNICAL SPECIFICATIONS AND SECURITY NOTES STANDARDS AND CERTIFICATIONS XTO-iP 210 Europe 868 MHz Compliant with Directive 2014/53/EU for RED Radio Equipment Directive XTO-iP 310 865/867 MHz India XTO-iP 733 915/928 MHz - FHSS Australia XTO-iP 830 C-Tick 902/907.