Installation Manual

2013/01/18 Ed 1 Setup and Programming manual for XTIP series
43 | P a g e
1375 Willow Lake Blvd. #103
Vadnais Heights, MN 55110
4. Finding Manufacture Week and Year:
The Manufacture week and year can be found in the serial number of the device/control panel. The
second sets of 4 numbers in the serial number are WWYY.
####0411######## = Which shows that this device was manufactured in the 4
th
week of 2011.
5. Event Log Ethernet Codes
Log Code
Meaning
Ethernet Off
Ethernet interface is OFF
Ethernet On
Ethernet interface is ON
Ethernet (0)
Ethernet Error
Ethernet (1)
No DCHP reply (after MAX DHCP RETRY)
Ethernet (2)
No Frontel reply (after TIMEOUT SERVER)
Ethernet (255)
Ethernet communication success
Ethernet Lost
No Ethernet cable detected
Ethernet Returned
Ethernet cable restored
6. Additional System Codes
Codes
Action
999999
Maintenance request - GPRS / 3G transmission
999996
Maintenance request - Ethernet transmission
999995
Displays local IP address assigned to the control panel:
If the DHCP mode is deactivated : the static local IP of the panel will be displayed
(defined in the ETHERNET menu7)
If the DHCP is activated:
If the panel is not in transmission then 0.0.0.0 will be displayed
If the panel is in transmission (the RJ45 led will be flashing) then the dynamic IP
of the panel will be displayed.
999991
Sends a test alarm to IP1 Address (Primary alarm receiver)
This is a quick way to check for connectivity to the monitoring center. If there is a
transmission problem the panel will terminate communication faster than in an actual alarm.
The system will automatically attempt connection to IP2 Address (Backup alarm receiver) in
the event that IP1 is unavailable.
999997
Displays external power supply status