Installation Manual
2013/01/18 Ed 1 Setup and Programming manual for XTIP series
39 | P a g e
1375 Willow Lake Blvd. #103
Vadnais Heights, MN 55110
Unable to record device or getting ‘Pairing Failure’ error
This usually occurs when the device still has a pairing key from a previous system or setup. To
perform a pairing key override:
o 1. Remove all batteries from the device.
o 2. Make sure your system is ready to record devices:
o A. If learning in the keypad, press the panel’s programming button. DO NOT
HOLD THE PANEL’S PROGRAMMING BUTTON
o B. If learning in additional devices, make sure the keypad reads ‘Press
Programming Button Of Device’
o 3. Insert a single battery into the device.
o 4. Wait 1 second for device to power up.
o 5. Press programming button of device (for keypads press ‘CLR’ & ‘ESC/NO’ keys at the
same time)
For the 4-button remote keyfobs the process is slightly different:
o 1. Press and hold the ‘ON’ and ‘OFF’ keys at the same time for 12 seconds
o 2. Wait 1 second
o 3. Press and hold the ‘ON’ and ‘OFF’ keys at the same time for 5 seconds, you should
hear 4 beeps from the keyfob.
Outdoor MotionViewer Trips All the Time:
It is important to follow these basic installation tips when mounting and aiming an outdoor
MotionViewer
o 1. Protect your assets, not the whole area.
Secure specific assets or clusters of assets rather than cover a large
area where the range of the MotionViewer might extend beyond the
assets and detect irrelevant objects.
o 2. Terminate the view of the MotionViewer.
Make sure to tilt the MotionViewer down 5-7° so that its top line of
sight terminates into the ground. Taking into account all three
elements; PIR, digital video camera, and infrared illuminators – you
will want to terminate the view of the MotionViewer at 40 ft. from the
device.