Installation Manual

2013/01/18 Ed 1 Setup and Programming manual for XTIP series
19 | P a g e
1375 Willow Lake Blvd. #103
Vadnais Heights, MN 55110
Entering a Badge or Access Code for Arming/Disarming
After Initial programming has been completed, you are not able to arm and disarm the system until
you enter a user code or badge (the installer code cannot arm and disarm the system). Codes can
be 4-6 digits and the 4
th
digit must be 2 values higher or lower than any other code on the system:
Example: User code 1234, next code cannot be 1235, 1236, 1233, or 1232 – These are reserved for
Silent Duress and Audible Duress. The XT system can accept up to 19 Badges or Access codes in
any combination.
Reserved codes
Reserved codes
Reserved codes
000000
From 9998 to 9999
All codes +1
From 99998 to 99999
All codes +2
From 999898 to 999999
All codes -1
From 314157 to 314159
All codes – 2
A total of 186 codes are forbidden
If you are entering any additional codes press YES/OK. If
you have completed entering Badges and Codes press and
hold ESC/NO for 5 seconds to return to the main menu.
Use the keypad to name the badge or code or leave it blank
for the default name: ACCESS #.
Confirm the code by re-entering.
Enter a 4-6 digit user code or present a badge to the reader
for 2 seconds.
You must first change the access level to 4. Right Arrow to
Access Level and press YES/OK. Use the arrow keys to
move to Level 4 and press YES/OK. When prompted with
Badge Or Code enter the installer code followed by YES/OK.
Press the arrow to move to BADGES ACCESS CODES.
YES/OK
YES/OK
YES/OK
YES/OK
CONFIRM THE
CODE:
Badge
Presented
NAME OF BADGE:
ENTER A
BADGE/CODE
YES/OK
YES/OK
CODE NAME:
BADGE OR CODE
****
ENTRY COMPLETE
ENTER A
BADGE/CODE
BADGE OR CODE:
****
ACCESS LEVEL:
4
10/12/27 10:53
DISARMED LVL:1
BADGES ACCESS
CODES
YES/OK