Installation Manual
2013/01/18 Ed 1 Setup and Programming manual for XTIP series
16 | P a g e
1375 Willow Lake Blvd. #103
Vadnais Heights, MN 55110
RECORDING
DEVICES
PRESS PROGRAM
BUTTON OF
DEVICE
ENTERING A NEW
DEVICE?
CLOSE THE PANEL
OPERATION
COMPLETED?
YES/OK
YES/OK
Each device has a unique programming button. Please
reference the Installation Sheet for the device you would like
to program.
Before completing programming make sure that all tampers
are depressed by verifying that each devices indicator LED is
off.
(Device Type) #
Recorded
RADIO RANGE
TEST?
RF TEST
x/9
RADIO RANGE
TEST?
AREA
ALLOCATION:
NAME LOCATION:
FUNCTIONAL
DEVICE TEST?
YES/OK or ESC/NO
Press YES/OK on Radio Range Test? You must allow the
Radio Range test to run for at least 30 seconds (9/9) before
stopping the test by pressing YES/OK.
Press ESC/NO if first Radio Range Test was successful.
Use the arrow keys to select the proper area. Devices that
need an entry/exit delay should be set to AREA 1. Devices
that must be instant trigger should be AREA 2, 3, or 4. Press
YES/OK.
*Note: If you are having issues pairing a device to the panel,
please refer to the troubleshooting section.
TRANSMISSION
DELAY
Value: (0-600)
(000):
ARMING
CONFIRMATION
Value: (0-240)
(0):
YES/OK
By entering a value using the keypad, up to 600 seconds,
the transmission of any event will be delayed that many
seconds.
Enter the value you would like for the Transmission Delay
and press YES/OK
Arming Confirmation is the number of seconds the system
will wait to arm after voltage is latched on the arming input.
This feature can be used as an exit delay.
Enter the value you would like for the Arming Confirmation
and press YES/OK