Installation Manual

2011/11/10 Ed 1.5 Setup and Programming manual for XT series GPRS
12 | P a g e
4455 White Bear Parkway, Suite 700
White Bear Lake, MN 55110
CODE/STATE
MODIFICATION ?
AREAS
CONFIGURATION
AREA NAME 1:
Other values are available:
2 min, 1 min, 45 sec
Use the arrows for the selection and YES to confirm.
Other values are available:
2 min, 1 min, 45 sec, 30 sec, 15 sec
Use the arrows for the selection and YES to confirm.
Use the Alphanumeric Keypad to name the area and press
YES. Repeat for all four areas. If you want to keep the
default area names press the ESC/NO key.
By default Area 1 is a delay area and Area 2, 3, & 4 are
instant areas.
CODE/STATE modification
These are the default transmitted events:
Device Alarm
Alert Alarm
Initialization Not Transmitted
Panel Batteries Alarm/End
AC Power Alarm/End
Phoneline Fault Not Transmitted
Tamper Alarm/End
Device Batt. Alarm/End
Radio Jamming Not Transmitted
Supervision Alarm/End
Periodic Test Alarm
Wrong Codes Not Transmitted
Duress Code Alarm
Alarm Memory Not Transmitted
Arm/Disarm Not Transmitted
If you would like to change the state
press YES and use the or to toggle
between:
Alarm Appearance
Alarm/End Appearance and Restoral
Not Transmitted Not Transmitted
If you would like the default press ESC/NO
Wait
TRANS. STATE
MODIFICATION
List of all
events
YES
ESC/NO
ESC/NO
EXIT DELAY:
45 Sec
ENTRY DELAY:
15 Sec
ARMING OPTION:
From the host
ARMING OPTION:
Standalone
ARMING OPTION: Your choice will depend on how you are
arming the system.
From the host: Will make the XT a piggyback/xtender
system that arms and disarms off the latching of 9-12v on
the arming inputs.
Standalone: Will make the XT a solo system controlled by
arming and disarming using Videofied peripheral devices.
Go to Page 10 if you
will be choosing this
option
Go to Page 11 to continue
with standalone programming