Installation Instructions
Electrical Data
Panel Compatibility Visio, XT, XL, XTIP
Power requirements
Type C
Nominal Voltage 3.6V
Low battery limit 2.7V
QTY and Battery Type One 3.6V Lithium battery
Battery type SAFT Lithium, LS14500
Battery life Up to 4 years
Current Consumption
Standby 30 uA
Max 70mA
Axis of detection Three axis (X, Y, Z)
Opening Detection Distance .9in (2.3cm)
Closing Detection Distance .8in (2.0cm)
RF technology S
2
View
®
Radio type Spread Spectrum Bidirectional RF
Operating frequency 915 MHz
Transmission security AES algorithm encryption
Supervision Polled signal every 8 minutes
Antenna Integrated
Tamper detection Wall and cover tampered
External terminal input type Normally closed (NC)
Working modes 1-internal reed switch only
2-external input only
3-internal switch and external input
Mode selection Jumper wire on 3-position terminal block
Maximum external wire length 16 m/50 feet
Operating temperature -10°/+40°C (14°/104°F)
Maximum relative humidity 75%, non-condensing
Approvals FCC Part 15C
Physical Data
Material Plastic: ABS—ULV0
Magnet Alnico 5
Dimensions 80 mm x 35 mm x 23 mm
(LxWxD): Detector: 3 1/8 in. x 1 3/8 in. x 1 in.
Weight: Detector 40 g/1.4 oz. –without battery
Installation/Mounting
Detector One screw secures detector to base;
two screws secure detector to mounting surface.
Magnet Two screws secure magnet
assembly to mounting surface.
Spacing Maximum 10mm (3/8) in gap
between detector and magnet.
INSTALLATION DATA SHEETDoor Contact CT601