Installation Instructions

Product Summary
The Door Contact Models CT601 is a wireless door/window
contact designed for use with RSI VIDEO Technologies
security systems. The contact includes the following
features:
>
Lithium battery for long life.
>
External input for normally closed (NC) intrusion devices.
>
Dual tamper function provides detection for both wall
and cover tamper.
>
Transmits check-in/status signal every 8 minutes.
Programming/RF Testing
The following provides summarized steps for device
programming and testing. For complete details, refer
to the control panel installation manual.
1
Loosen bottom screw, separate base
from detector and install battery.
2
Re-attach base to secure tamper switch.
3
Put control panel into programming/
configuration mode.
4
Using a programmed alphanumeric
keypad, proceed through menus
until the display shows ADD A
NEW DEVICE.
5
Press Yes. The display shows
PRESS PROGRAM BUTTON OF DEVICE.
6
Press and release program button on detector using a
paper clip end. The detector LED flashes. Wait for keypad
display to show DETECTOR (1 - 25) RECORDED.
7
Press Yes. The display shows RADIO RANGE TEST?
Press Yes again. The detector LED starts flashing and
keypad display shows TEST IN PROGRESS.
8
Take detector to its intended mounting location and
make sure LED flashes continuously, indicating good
communication with control panel.
9
Press Yes to end radio range test, then press Esc/No.
10
The display shows AREA
ASSIGNMENT AREA: 1. Press
either arrow button repeatedly
until desired AREA number
appears, then press Yes.
11
The display shows PROTECT AN
EXTERNAL ACCESS? Press Yes or
Esc/No, whichever is appropriate
for this device.
12
The display shows NAME + LOCATION.
Enter appropriate device name/location (up to
16 characters), then press Yes. The display shows
the device number and name for your verification.
13
Press Yes. The display shows FUNCTIONAL DEVICE
TEST? Press Yes again and verify detector operation.
For example, move magnet next to detector to make
LED go out, then move magnet away from detector
to make LED turn on indicating detection.
14
Press Yes to end detection verification.
15
The display shows ENTERING A NEW DEVICE?
Repeat steps 1 - 14 for remaining detectors.
16
When finished, exit from configuration mode.
Installation Guidelines
For easier installation, programming and RF testing should
be done to check for good communication between the
control panel and all system devices before mounting
system devices. Install the detector and other system
devices in the following order:
>
Programming/RF Testing - program detector and
all other devices into the control panel and test RF
communication from each intended device location
to the control panel.
>
Mounting - mount detector at the tested location.
Remark: Only recorded contacts protecting the external access will be concerned by the Perimeter arming.
Use the keypad to activate Perimeter only arming. Press on (to activate the keypad), then shows on the
keypad enter a user code and validate with the key .
Screw
Program Button
LED
PRODUCT INSTALLATION SHEET
Door/Window Contact CT601
2209-CTIS March 2012Made by RSI VIDEO TECHNOLOGIES