Service manual
Electrical Service Manual V4.0
6
6-13
CENTRAL COMMAND II
VERSION 4
1. BATTERY METER
2. WATER VOLUME
3. BRUSH PRESSURE
4. BRUSHES OPERATING
5. WATER VALVE POWER ON
6. SUDS SYSTEM ICONS
7. VACUUM MOTOR OPERATING
8. HIGH THROTTLE DISABLE
SCREEN 1
Screen 1 is the default screen that appears after the machine
has powered up.
1: BATTERY METER - This meter shows the charge level of
the batteries in the machine. This gauge is designed to read
properly while the machine is in use and therefore will vary
both up and down during usage of the machine.
2: WATER VOLUME - This icon shows when the output vol-
ume that the controller has set.
3: BRUSH PRESSURE GAUGE - This icon is a bar graph
representation of the desired brush pressure. It is divided into
5 segments and each segment indicates more pad pressure.
4: BRUSHES OPERATING - This icon shows when the con-
troller receives an input to run the scrub brushes
5: WATER VALVE OPERATING - This icon indicates that the
controller is receiving an input to dispense water. The icon
flashes in relationship to the amount of time the valve is on
for. This is controlled by the solution potentiometer or solution
toggle switch on the control panel.
6: SUDS SYSTEM ICON - This icon indicates that the SUDS
system in turned on. When the SUDS system is on setting 1
there are 2 sets of bubbles that show and when the SUDS sys-
tem is on setting 2 (HI) there are 4 sets of bubbles that show..
7: VACUUM MOTOR - This icon indicates the controller is
receiving an input to run the vacuum motor.
8: HIGH THROTTLE DISABLE - This icon indicates one or
more throttle inputs, such as the green handle bar buttons
or the reverse switch, were activated when the machine was
powered on. Make sure no buttons or switches are de-
pressed and cycle the power to the machine.