Service manual
Electrical Service Manual V4.0 
5
5-3
CURTIS 1228 CONTROLLER
DIAGNOSTICS
FLASH CODES
To assist in the diagnosis of problems the controller has a remote LED indicator that flashes 
diagnostic codes. This LED is located either on the side or on the bottom of the central 
command. During normal operation, with no faults present, the status LED is steadily on. 
If the controller detects a fault, the status LED provides two types of information. First, it 
displays a slow flash (2 Hz or 2X a second) or a fast flash (4Hz or 4X a second) to indicate 
the severity of the fault. Slow flash faults are self-clearing; as soon as the fault is corrected, 
the machine will operate normally. Fast-flash faults (“*” in the table below) are considered 
to be more serious in nature and require that the key switch be cycled to resume operation 
after the fault is corrected.
After the severity indication has been active for 5 seconds, the Status LED flashes a 2-digit 
fault identification code continuously until the fault is corrected. For example, code “4.1” -- 
low battery voltage and code “3.2” -- electromagnetic brake driver appear as.:
Table 2 STATUS LED FAULT CODES
LED CODES EXPLANATION
 
 
  
  
  
  
  
  
  
  
�    
 
  
 
  
 
  
 
  
�    
�    
�     
�    
�  
 
  