2/16/2006 2023-04 RESETTABLE CIRCUIT BREAKER R&R
Page 4 of 5
HELP HOTLINE: 800-634-4060
REMOVING THE 2 AMP RESETTABLE CIRCUIT BREAKER
1. Using a needle nose pliers carefully disconnect the two pink wires from
the back of circuit breaker. NOTE: MAKE SURE TO GRAB
CONNECTORS NOT WIRES. (see figure below)
REMOVING THE 25, 30, OR 40 amp RESETTABLE CIRCUIT BREAKER
1. Using # 2 Phillips screw driver carefully remove the Qty:(2) 8/32’’
screws that hold the # 10 ring connectors to the circuit breaker. (see
figure below)
2. Using pliers loosen and remove the knurled nut on the front of the
control panel and remove the circuit breaker. (see figures below)
INSTALLING THE 2 AMP RESETTABLE CIRCUIT BREAKER
1. Install resettable circuit breaker and knurled nut.
2. Using a pliers carefully tighten the knurled nut snug.
3. Plug wires back into resettable circuit breaker.