Service manual

Table Of Contents
2023 Service Manual V1.0
RI
RI-13
REPAIR INSTRUCTIONS
2/16/2006 2023-04 RESETTABLE CIRCUIT BREAKER R&R
Page 1 of 5
HELP HOTLINE: 800-634-4060
TIME REQUIRED: 30 MINUTES
NUMBER OF TECHS: 1 PERSON
REQUIRED PARTS: SELECT THE APPROPRIATE CIRCUIT BREAKER
Qty: (1) actuator 2 amp resettable circuit breaker 7-837
Qty: (1) brush motor 30 amp re-settable circuit breaker 290-9609
Qty: (1) HD brush motor 40 amp re-settable circuit breaker
190-9609
Qty: (1) vacuum motor 25 amp re-settable circuit breaker 190-8370
REQUIRED TOOLS
# 2 Phillips screw driver
Pliers
Needle nose pliers
9/16’’12-point deep well socket
COMPLETELY DRAIN SOLUTION & RECOVERY TANKS
MAKE SURE MACHINE IS ON LEVEL GROUND AND WHEELS ARE
CHOCKED AND SCRUB DECK IS IN UP POSITION.
OPENING TANK
1. Locate and remove the 3/16’’ Allen wrench on the right side of scrub
deck. (see figure below)
3/16 Allen wrench
2. Locate and remove the two 5/16’’-18 x 3’’ bolts that are in the relief
ports on the left and right sides of machine. (see figure below)
Relief port