Service manual
Table Of Contents

2023 Service Manual V1.0 
RI
RI-13
REPAIR INSTRUCTIONS
2/16/2006  2023-04 RESETTABLE CIRCUIT BREAKER R&R
Page 1 of 5
HELP HOTLINE: 800-634-4060 
TIME REQUIRED: 30 MINUTES
NUMBER OF TECHS: 1 PERSON
REQUIRED PARTS: SELECT THE APPROPRIATE CIRCUIT BREAKER
�  Qty: (1) actuator 2 amp resettable circuit breaker 7-837 
�  Qty: (1) brush motor 30 amp re-settable circuit breaker 290-9609 
�  Qty: (1) HD brush motor 40 amp re-settable circuit breaker
190-9609
�  Qty: (1) vacuum motor 25 amp re-settable circuit breaker 190-8370
REQUIRED TOOLS 
�  # 2 Phillips screw driver 
�  Pliers 
�  Needle nose pliers 
�  9/16’’12-point deep well socket 
COMPLETELY DRAIN SOLUTION & RECOVERY TANKS
MAKE SURE MACHINE IS ON LEVEL GROUND AND WHEELS ARE 
CHOCKED AND SCRUB DECK IS IN UP POSITION.
OPENING TANK
1.  Locate and remove the 3/16’’ Allen wrench on the right side of scrub 
deck. (see figure below) 
3/16 Allen wrench 
2.  Locate and remove the two 5/16’’-18 x 3’’ bolts that are in the relief 
ports on the left and right sides of machine. (see figure below) 
Relief port