Service manual

Table Of Contents
2023 Service Manual V1.0
RI
RI-12
REPAIR INSTRUCTIONS
2/16/2006 2023-03 SOLUTION FLOW VALVE R&R Page 5 of 5
HELP HOTLINE: 800-634-4060
REINSTALLING SOLUTION FLOW VALVE
1. Hold new solution flow valve in position and install the ¼’’-
20x1/2’’ bolt and ¼’’20 nut and tighten.
2. Reinstall the ball valve onto solution flow valve and tighten
using a 13/16’’ open wrench. NOTE DON’T OVER TIGHTEN.
3. Reinstall ½’’ hose and clamp on to ball valve and tighten
the ½’’ hose clamp using a 3/16’’ flat head screw driver.
4. Reconnect the orange and black wire to the solution flow
valve.
5. Reinstall the 8’’ wire tie to hold the orange and black wire
to the solution flow valve.
6. Reconnect the batteries.
7. Carefully lean tank into position.
8. Reinstall the Qty: (2) 5/16’’-18x3’’ bolt into the relief ports
and tighten.
9. Reinstall the 3/16’’ Allen wrench into its location.