Service manual

Table Of Contents
2023 Service Manual V1.0
RI
RI-9
REPAIR INSTRUCTIONS
2/16/2006 2023-03 SOLUTION FLOW VALVE R&R Page 2 of 5
HELP HOTLINE: 800-634-4060
NOTE: IF MACHINE HAS KEY SWITCH, REMOVE KEYS BEFORE NEXT
STEP.
3. Carefully lean tank back to expose battery compartment.
DISCONNECTING BATTERIES
1. Locate the positive terminal that is in front left of battery pack.
2. Using a 9/16’’ 12- point socket loosen and remove the 5\16’’ nut.
3. Remove the red cable and secure away from terminal .( See figure
below)
REMOVING SOLUTOIN FLOW VALVE
1. Using a 3/16’’ screw driver loosen the ½’’ hose clamp that holds the
½’’ reinforced hose to the ball valve. (see figure below)