Service manual
Table Of Contents

2023 Service Manual V1.0
6
6-4
SOLUTION SYSTEM
Use a voltmeter to
test f
or voltage
ac
ross the deltrol
valve termina
ls
when the green
handle bar button
is depressed
Do you have 24 Volts?
Check the screw
on t
he back of the
delt
rol valve and
mak
e sure it is
backed out all th
e
wa
y
Check for 24 Volts
into the solutio
n
switch when the
green handle
bar
button is depresse
d
YES
NO
Do you have 24 volts
into the switch?
Check the wiring
between the b
rush
motor solenoid and
the water switch on the
control panel
NO
Do you have 24 Volts
out of the w
ater switch in
the o
n position?
YES
YES
NO
Does the scrub deck
tur
n on when the green
button is depressed?
YES
See “Brush drive system”
sectio
n
NO
Was the screw backed
out all the way an
d
secured wit
h a locknut?
Back out all the way and
install lock nut. Retest
machine
NO
Use your meter to
check for
continuity on the
deltrol valve
Was there
res
istance or an
open c
ircuit?
Call the factory
Replace the deltrol valve
Open circuit
Resistance
Replace the switch.
Retest the mac
hine.
YES
Do you have 24
volts on the orange
wir
e at the deltrol
va
lve?
Repair wiring from the solution
switch to the deltrol valve.
Retest Machine
NO
Do you have ground
at the coil circuit
of the
solution relay?
YES
Call the factory
Repair the wiring from the
negative buss bar.
Retest machine
NO
YES
From
Previous
Page
SOLUTION SYSTEM DIAGNOSIS FLOW CHART 2 of 2