Service manual
Table Of Contents

2023 Service Manual V1.0 
6
6-2
SOLUTION SYSTEM
ADJUSTING SOLUTION FLOW
To adjust the solution flow use the ball valve 
mounted on the right side of the brush deck. 
(Note: Early production models did not have a 
ball valve. On these models the solution sole-
noid valve is adjusted to control the amount of 
solution flow.)
CLEANING SOLUTION FILTER
Drain solution tank with the drain hose. Re-
move squeegee tool from the machine. Lower 
the squeegee linkage. Reach under the ma-
chine and unscrew and remove the clear part of 
the plastic filter housing. Remove screen and 
clean. Replace screen and clear part of filter 
housing.
DRAINING SOLUTION TANK
Detach the solution drain / sight gauge hose 
from the upper barb and lower into a suitable 
drain or receptacle. When the solution has 
emptied reattach the hose to the upper barb.
SOLUTION DRAIN/
SIGHT GAUGE
SOLUTION 
SOLENOID 
VALVE
SOLUTION 
FILTER