Service manual

Table Of Contents
2023 Service Manual V1.0
6
6-2
SOLUTION SYSTEM
ADJUSTING SOLUTION FLOW
To adjust the solution flow use the ball valve
mounted on the right side of the brush deck.
(Note: Early production models did not have a
ball valve. On these models the solution sole-
noid valve is adjusted to control the amount of
solution flow.)
CLEANING SOLUTION FILTER
Drain solution tank with the drain hose. Re-
move squeegee tool from the machine. Lower
the squeegee linkage. Reach under the ma-
chine and unscrew and remove the clear part of
the plastic filter housing. Remove screen and
clean. Replace screen and clear part of filter
housing.
DRAINING SOLUTION TANK
Detach the solution drain / sight gauge hose
from the upper barb and lower into a suitable
drain or receptacle. When the solution has
emptied reattach the hose to the upper barb.
SOLUTION DRAIN/
SIGHT GAUGE
SOLUTION
SOLENOID
VALVE
SOLUTION
FILTER