BLOWER PERFORMANCE DATA (DOWNFLOW)
MODEL
MOTOR
SIZE (HP)
BLOWER
SIZE
HEATING
TEMP.
RISE
(°F)
HEATING CFM @ .10" - .80" W.C.
COOLING
STAGE
COOLING CFM @ .10" - .80" W.C.
SPEED
ADJUST.
SETTING
"D"
SETTING
"C"
SETTING
"B"
SETTING
"A"
SETTING
"D"
SETTING
"C"
SETTING
“B”
SETTING
"A"
DOWNFLOW
96G2DF070BV16 3/4 11x10
35-65
High
Fire
1110 1305 1430 1700
2nd
Stage
1110 1340 1575 1800 +
995 1175 1315 1520 995 1230 1420 1650 Norm
880 1055 1170 1365 880 1085 1290 1460 -
25-55
Low
Fire
860 1020 1140 1340
1st
Stage
740 915 1055 1255 +
795 910 1030 1230 660 820 940 1120 Norm
680 825 910 1085 575 735 850 995 -
96G2DF090CV20 1 11x11
40-70
High
Fire
1395 1555 1695 1825
2nd
Stage
1335 1600 1750 1980 +
1275 1395 1585 1670 1225 1450 1630 1830 Norm
1145 1265 1405 1525 1120 1270 1450 1660 -
30-60
Low
Fire
1130 1230 1365 1475
1st
Stage
955 1115 1265 1450 +
1040 1130 1250 1340 855 1005 1150 1285 Norm
910 1025 1130 1210 750 890 1060 1170 -
96G2DF110CV20 1 11x11
45-75
High
Fire
1595 1795 1955 2010
2nd
Stage
1335 1585 1790 2010 +
1450 1615 1795 1865 1220 1440 1630 1865 Norm
1290 1460 1610 1680 1100 1275 1475 1680 -
35-65
Low
Fire
1165 1305 1465 1547
1st
Stage
920 1095 1265 1440 +
1055 1185 1315 1404 830 965 1130 1290 Norm
930 1070 1180 1272 735 860 1035 1155 -