Specification
SPLIT SYSTEM AIR CONDITIONER 4AC13
Page 13
Outdoor Model
Indoor
Model
Variable
Speed
Furnace
SEER EER
Rated
ARI
Capacity
1
BTUH
Rated
Sensible
Capacity
BTUH
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor
Expansion
Device
Evaporator
Coil
or
Air Handler
3
Outdoor Indoor
Suction
Liquid
Piston
2
TXV
Suction
Liquid
Suction
Liquid
4AC13*42P
BCS2M48V****P
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
0.075
A4TXV02
E(C,H,M,U)1P43B 80G1DF090BE16
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43B 80G1UH090BE16
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43B 95G1DF070BE16
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 80G1DF110CE20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 80G1UH090CE20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 80G1UH110CE20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 95G1DF090CE16
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 95G1DF110CE20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 95G1UH090CE16
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 95G1UH110CE20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 95G2DF090CV20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 95G2DF110CV20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 95G2UH090CV20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,M,U)1P43C 95G2UH110CV20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 80G1DF110CE20
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 80G1UH090CE20
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 80G1UH110CE20
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 80G2UH110CV20
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 95G1DF090CE16
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 95G1DF110CE20
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 95G1UH090CE16
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 95G1UH110CE20
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 95G2DF090CV20
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 95G2DF110CV20
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 95G2UH090CV20
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,H,U)1P49C 95G2UH110CV20
13.5 11.0 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,M,U)1P50C 80G1DF110CE20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,M,U)1P50C 80G1UH090CE20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,M,U)1P50C 80G1UH110CE20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
E(C,M,U)1P50C 80G2UH110CV20
13.5 11.5 40,000 29,200 1400 7/ 8 3/8 7/ 8 3/8 3/4
6
3/8
COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES
* = B or L B = Wire Guard L = Louvered
Note:
1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240
2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required.
3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products.
4 For lines 25 ft or over, use 3/8"
5 For lines 25 ft or over, use 3/4"