TROUBLE SHOOTING
Problem Cause Solution
Machine does not work
Unit is not plugged in Plug in the unit
Room temperature is <5°C or above 35°C
(<41°F, >95°F).
To protect the machine, use it only when ambient
temperature is between 5 and 35 degrees.
Machine runs but does not
dehumidify
The humidity set point is 2% higher than ambient
humidity.
Reset the humidity to a lower set point .
Reduced dehumidifier capacity
Filter mesh is jammed Clean the filter mesh
Air-in and/or Air-out louvers jammed. Clear the blockage of the Air-in and/or Air-out louvers.
No air inlet Filter mesh or air-in louver jammed.
Clean filter according to instructions or clean the louver
blockage
Loud Operation
Machine situated on an incline or decline slope Move to a flat ground
Filter mesh is jammed. Clean filter mesh according to instructions
Cautions: Switch off the unit and unplug it immediately if anything abnormal happens. Contact a qualified electrician.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.