Installation Guide
12
SPECIFICATIONS
Model Capacity (Pints/Day) Power input Amps
High side pressure Low side pressure
Refrigeration
RDH-330 30Pint/24Hrs 115V 60Hz 4.0A 530Psig(3.7Mpa) 320Psig(2.2Mpa)
R410A/4.94Oz
RDH-370 73Pint/24Hrs 115V 60Hz 8.1A 530Psig(3.7Mpa) 320Psig(2.2Mpa)
R410A/9.52Oz
RDH-370 73Pint/24Hrs 115V 60Hz 8.1A 530Psig(3.7Mpa) 320Psig(2.2Mpa)
R410A/9.52Oz
Problem Possible Causes Solutions
Dehumidifier runs
too much
• The area to be dehumidified is too large.
• Doors and windows are open.
• The capacity of your dehumidifier may not be adequate for the room size.
• Close all doors and windows to the outside.
Frost appears on
the coils
• The dehumidifier has recently been turned on or the
• This is normal. Frost will usually disappear within 60 minutes.
Controls cannot
be set
• The compressorwill turn off and the fan will
automatically continue to run for approximately 3
minutes at a fixed setting.
• Air is moving through the unit.
• This is normal. Wait approximately 3 minutes and set the fan speed at the desired level.
• This is normal.
Water on the
floor
• Hose connection may be loose.
• Hose is attached but not draining
• Check the hose connection. See the CONTINUOUS MODE- GARDEN HOSE INSTALLATION
AND SET UP Section
• Disconnect the hose if using the bucket or place the hose near a drain.
ERROR CODE
Error code
EH E1 or E2 E3 E5 P1
Description
Humidity sensor fault Temperature sensor fault Lack of gas to protect Pump sensor fault
Tank dislocation or
removed