Installation Guide
14
Error Code Description
EH Humidity sensor fault
E1 or E2 Temperature sensor fault
E3 Lack of gas to protect
E5 Pump sensor fault
P1 Tank dislocation or removed
ERROR CODES
MODEL RDH-230 RDH-270 RDH-270P
Capacity
(Pints / Day)
30 Pints / 24 Hrs. 70 Pints / 24 Hrs. 70 Pints / 24 Hrs.
Power Input 115V / 60Hz 115V / 60Hz 115V / 60Hz
Amps 3.0 A 8.1 A 8.1 A
High Side Pressure 530 psig (3.7 mpa) 530 psig (3.7 mpa) 530 psig (3.7 mpa)
Low Side Pressure 320 psig (2.2 mpa) 320 psig (2.2 mpa) 320 psig (2.2 mpa)
Refrigeration R410A / 5.29oz R410A / 9.35oz R410A / 9.35oz
Unit Dimensions
(W x D x H)
13.40”W x 10.15”D x 19.50”H
340mm x 258mm x 495mm
14.96”W x 11.34”D x 24.80”H
380mm x 288mm x 630mm
14.96”W x 11.34”D x 24.80”H
380mm x 288mm x 630mm
Unit Weight 30.8 lbs. / 13.97 kgs. 46.9 lbs. / 21.32 kgs. 49.4 lbs. / 22.4 kgs.
SPECIFICATIONS