Owner Manual
18
Troubleshooting Guide
Problems Explanations Solutions
1
Power
indicator
light not on
Power cord is not plug-in 1. Check for power to the outlet.
2.Check connection between power
cord and main control unit.
The fuse is burned out Check or replace the fuse.
2
Function
indicator
light not on
The corresponding
indicator light is
broken or burned out.
Repair or replace the control
panel.
The wiring or some
electronic component in
the circuit has failed
Repair or replace what has failed in
that circuit.
3
Infrared
Heater will
not heat up
The heater is
b
roken Replace with a new heater of the same
specifications.
Its life will be shortened
gradually from excessive
use.
The fuse is burned out. Check or replace the fuse.
The wiring connection for
the heater is loose or in
the wrong location.
Check it, and reconnect tightly.
The circuit board is not
functioning.
Check power output on the circuit
board
4
Sauna room
not
maintaining
correct
temperature/
Display shows
E1
Problem with heater. See Item #3.
Incorrect setting on
control panel
Reset it.
The temperature sensor
wiremaybelooseor
broken.
Check sensor wire connection and
condition. Check to see if sensor head
is visible inside the sauna room.
5
Peculiar
burning
smell
Circuit problems (broken
component, short circuit,
failure of controlling
system) causing the
burning of some
component in the
electrical system
1. Unplug sauna, check the voltage.
2. Find the objects with problems
3. Replace the parts
6
The light not
working
The light bulb is burned
out. Replace light
Replace light bulb.
The bulb is not secured in
the base
1.Make sure the bulb is tight enough
to make good contact in the light
fixture.
2.Check the lighting protection fuse.
The socket is
b
roken. Replace it.
Problems with electrical
control panel.
Check or replace the panel.