User manual
WiFly GSX
WiFlyGSX-um.pdf 12/14/2009
www.rovingnetworks.com
support@rovingnetworks.com
Phone 408-395-6539
- 12 -
challenge <string>. When set, all newly opened connections must
first send the exact characters that match the stored password
otherwise the WiFly module will close the connection. When the
password is set the WiFly module sends the string “PASS?” to the
remote host. All characters in the string must be sent in one TCP
packet. Max string size is 32 bytes. To disable the password feature
use string=0 which is the default.
5.8 SYSTEM Parameters
set sys autoconn <secs> TCP mode: sets the auto connect timer. This command causes the
module periodically connect to the host. The timer <secs>
determines how often to connect to the stored remote host. If set to
1, the module will only make one attempt to auto connect upon
power up. If set to 2 or greater auto connect will re-open the
connection after the connection is closed. Default=0 disables.
set sys autosleep <num> Sets the auto-sleep timer. 0 disables. If the protocol is set to UDP
ONLY, this timer is used as a quick sleep function. Device will sleep
<num> ms after transmission of the first UDP packet.
set sys iofunc <value> sets the IO port alternate functions. Bit-mapped value. For more
details see section 10.5
set sys mask <mask> sets the IO port direction mask. Bit-mapped value. For more
information see section 10.5
set sys printlvl <value> sets numerous print functions. 0 = quiet 1 = connect information
Default is 1.
set sys output <value> <mask> sets output PIO pins to HIGH or LOW. Bit-mapped value.
Optional mask only sets a subset of pins.
set sys sleep <secs> sets the sleep timer. 0 disables.
NOTE: If not using Sensor pins to wake the module, be sure to set
the wake timer before issuing the sleep timer or the module will not
wake up.
See section 10.1 for more details on using system timers
set sys trigger <value> sets the sensor input(s) to wake on (0-3). Bit-mapped value. 0
disables.
set sys wake <secs> sets the auto wake timer. 0 disables. See section 10.1 for more
details on using system timers
5.9 TIME Server Parameters
set time address <addr> sets the time server address. (sNTP servers)