User manual
WiFly GSX
www.rovingnetworks.com
WiFlyGSX-um 7/16/2010
809 University Avenue • Los Gatos, CA 95032 • Tel (408) 395-6539 • info@RovingNetworks.com
~ 51 ~
Join timer/WPA timer 1000
Replacement char $ (0x24)
Format 0x00
Password “” (no password enforced)
Sensor 0x00
SYSTEM PARAMETERS
Sleep timer 0
Wake timer 0
Trigger 1 (SENS0 pin wakes up the device)
Auto connect 0
IOfunc 0 (no alternate functions )
IOmask 0x21F0
Print level 1 (prints enabled)
TIME SERVER PARAMETERS
Enable 0 (disabled)
Server address 129.6.15.28 (fixed to port 123 - SNTP protocol)
Zone 7 (pacific USA time)
UART PARAMETERS
Baudrate 9600
parity n (none, this is the only option available)
flow 0 (disabled)
Mode 0
WLAN PARAMETERS
SSID roving1
Channel 0 (automatic scan )
External antenna 0 (off - use on-board chip antenna)
Join mode 1 (automatically scan and join based on ssid )
Authentication mode OPEN
Mask 0x1FFF ( all channels )
Rate 12 (24Mbit)
Passphrase rubygirl
Key number 1
Key 0 0 0 0 0 0 0 0 0 0 0 0 0
17.1. Restoring Default configuration settings:
From command interface use the factory RESET command to restore the defaults. This command
automatically loads default settings, and executes a “save” command.
From hardware, setting PIO9 high on power up arms the factory reset functional and toggling PIO9 five (5)
times there after causes the configuration setting to restored to the factory reset.