10.6. Setting Debug Print levels
There are a number of print functions that can be enabled to assist in debugging the operation and status of
the module. The following command is used to control these printouts.
set sys printlvl <value> sets additional print functions. Value is a bit-mapped register that controls which
printout messages are sent to the UART.
Print level Description
1 All status messages
2 only critical NETWORK AP connection level status is output, "Associated!" Or
"Disconnect from <ssid>"
4 DHCP and IP address status information Once the configuration has been checked; this
can then be turned off so that these messages do not interfere with the data.
10.7. Using the Real Time Clock Function
The real time clock in the module keeps track of the number of seconds since the module was powered on
and the actual time when synchronized with the sNTP time server. By default the module keeps track of up
time but does not synchronize with the time server since this requires being associated with a network that
can access the sNTP server.
The default sNTP server is at
ADDR=129.6.15.28:123
ZONE=7 (GMT -7)
Use the show time command to see the current time and uptime
<2.20> show t
Time=08:43:10
UpTime=10 s
Time can be set by using the time command
<2. 20> show t
Time NOT SET
UpTime=8 s
<2. 20> time
<2. 20> show t
Time=08:51:31
UpTime=15 s