Product Manual
Thank you very much for choosing a Roughneck® Product! For future reference, please
complete the owner’s record below:
Model: _______________ Purchase Date: _______________
Save the receipt, warranty and these instructions. It is important that you read the entire manual
to become familiar with this product before you begin using it.
This machine is designed for certain applications only. The distributor cannot be responsible for
issues arising from modification. We strongly recommend this machine is not modified and/or
used for any application other than that for which it was designed. If you have any questions
relative to a particular application, DO NOT use the machine until you have first contacted
distributor to determine if it can or should be performed on the product.
For technical questions, please call 1-800-222-5381.
WARNING: Read carefully and understand all INSTRUCTIONS before operating.
Failure to follow the safety rules and other basic safety precautions may result in
serious personal injury.
Save these instructions in a safe place and on hand so that they can be read when required.
Keep these instructions to assist in future servicing.
INTRODUCTION
The fuel box is made from high density polyethylene material. 1PC DC pump equipped with the
suction pipe, delivery hose and nozzle are fixed and installed internal of the box. For more
convenient operation, the pump and fittings are connected by rotating swivel connector.
PUMP: self-priming, volumetric, rotating vane pump, equipped with by-pass valve. With the
3/4in. rotating swivel connector.
The pump is designed to transfer diesel fuel only, for intermittent use with a working cycle of 30
minutes under maximum back pressure conditions.
MOTOR: Brush motor, DC, low tension with intermittent cycle, closed type in protection class
IP55, directly flanged to the pump body.
SUCTION TUBING:
- Minimum recommended nominal diameter: 3/4in.
- Nominal recommended pressure: 10bar/145PSI
- Use tubing suitable for functioning under suction pressure
DELIVERY TUBING:
- Minimum recommended nominal diameter: 3/4in.
- Nominal recommended pressure: 10bar/145PSI
Nozzle:
- Aluminum Manual nozzle
- Connection: 3/4in.
TECHNICAL SPECIFICATIONS
Portable Fuel Transfer Box Kit
OWNER’S MANUAL
Portable Fuel Transfer Box Kit OWNER’S MANUAL
Item#s 41874
1 of 9
WARNING: Read carefully and understand all INSTRUCTIONS before
operating. Failure to follow the safety rules and other basic safety
precautions may result in serious personal injury.
Model No.
Electrical power
Current
Fuses
Working pressure
Flow rate range
Delivery hose
41874
DC 12V
Max. 24 Amp
25
Max. 18 PSI
40 LPM/ 10GPM
3/4in. x 13ft.